Symbol PDT 8100 Series Product Reference Manual page 208

Hide thumbs Also See for PDT 8100 Series:
Table of Contents

Advertisement

PDT 8100 Series Product Reference Guide
Problem
Tapping the screen
buttons or icons does
not activate the
corresponding feature.
A message appears
stating that your PDT
8100 terminal memory
is full.
Beamed data does not
transmit.
When receiving
beamed data an out of
memory message
appears.
13-4
Table 13-1. Troubleshooting the PDT 8100
Cause
LCD screen not aligned
correctly.
Too many files stored on
the terminal.
Memory allocation too
low.
Too many applications
installed on the terminal.
PDT 8100 terminals too
close together.
Insufficient room
lighting.
Not enough free memory
available for receiving
data.
Solution
Align the screen. Choose Align Screen
from the System tab under Start/Settings,
or hold down the Function button and press
the Enter (Action) key.
Delete unused memos and records. You
can save these records on your computer.
Adjust the memory allocation. Select Start,
then Settings, and select the System tab.
Tap Memory and adjust the slider.
If you have installed additional applications
on your PDT 8100, remove them to recover
memory. Select Start, then Settings, and
select the System tab. Tap Remove
Programs, select the unused program and
tap Remove.
Confirm that the PDT 8100 terminals are 5"
apart, and there is a clear path between the
two devices.
Adjust the room lighting or move to a
different location.
Your PDT 8100 terminal requires at least
twice the amount of memory available as
the data you are receiving. For example, if
you are receiving a 30K application, you
must have at least 60K free.