Set Up Rf Hazard Zones - KVH Industries V7 Installation Manual

32" (82 cm) configuration
Hide thumbs Also See for V7:
Table of Contents

Advertisement

Set Up RF Hazard Zones

15
To prevent exposure to RF energy, which might
be harmful to people who stand within 36 feet
(11 meters) of the antenna, you can configure up
to two RF radiation hazard zones for areas where
crew and/or passengers frequent (see Figure 42).
The system will disable the transmitter whenever
the antenna is pointing within one of these zones.
Follow these steps to set up an RF hazard zone.
a. Determine the necessary azimuth range for
the RF hazard zone(s). You will need to enter,
in clockwise order, beginning and ending
azimuths (>4° apart) relative to the antenna's
forward arrow, which should be pointing
toward the bow (see Figure 43).
b. At the control unit, press MENUS until the
display shows "CONFIGURATION." Then
press ACCEPT.
c. Press MENUS until the display shows "SET
HAZARD ZONE."
d. Press CHANGE until the display shows "SET
HAZARD ZONE = YES." Then press
ACCEPT.
e. At "ZONE 1," press CHANGE. A cursor
appears under the first number in the
azimuth range for RF hazard zone #1.
f. Press CHANGE until the number is set to the
first digit of the beginning azimuth for the
first hazard zone (enter a zero if < 100°).
g. Press ACCEPT. The cursor moves to the next
number.
h. Repeat steps f and g to set the remaining
digits of the desired RF radiation hazard
zone. Then press ACCEPT.
i.
At "Zone 2," repeat steps e-h to set the range
for the second RF hazard zone, if desired.
j.
At "XMT IN ZONES," verify that the display
shows "XMT IN ZONES = NO." Then press
MENUS.
k. Press EXIT to exit the menu.
NOTE: For more details, refer to the Configuration
section of the User's Guide.
Figure 42: Example of an RF Radiation Hazard Zone
Hazard Zone
080
015
Figure 43: Azimuths Relative to Antenna's Forward Arrow
Beginning
Azimuth
015
000
315
Forward
Antenna
270
225
180
Figure 44: Setup Process for RF Hazard Zones
ZONE 1= 015-080
CHANGE
ACCEPT
ZONE 2= 999-999
NEXT ITEM
CHANGE
XMT IN ZONES= NO
NEXT ITEM
CHANGE
Optional
RF Radiation
Hazard Zone
(Example)
Ending
Azimuth
080
090
135
Step 1:
Set Zone 1
Azimuth Range
Step 2:
Set Zone 2
Azimuth Range
Step 3:
Set to "NO"
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tracphone v7

Table of Contents