1.6 Burners & Rating
GC901/GC901M
Australia/New Zealand
NG
Orifice
(1kPa)
Size
(mm)
MJ/h
Auxiliary/
3.6
0.85
Simmer
Front Right
Semi Rapid
6.0
1.1
Rear Left
Rapid
Right Rear &
8.4
1.3
Front Left
Wok Centre
-
901
Wok Centre
15
1.8
901M
Note: Kits of high altitude orifices are available for GC901 and GC901M models.
NG Part No. 531566 LPG part no. 531567
These orifices should be used at approximately 6000 feet or above.
Serial and model numbers are located on the underside of the product. An extra label is provided to the installer to be placed in a
convenient location.
LPG
Orifice
(2.75kPa)
Size
MJ/h
(mm)
2.7
0.45
6.2
0.7
8.4
0.8
-
-
-
15
1.08
Great Britain / Ireland CG901/M
NG (I
)
Orifice
LPG (I
2H
3+
(20mbar)
Size
(28-30/37
(mm)
kW
mbar) kW
1.0
0.75
1.2
2.0
1.0
1.7
2.0
1.0
2.0
4.2
1.55
3.6
5.5
1.69
5.5
- 6 -
USA/Canada GC901/M
)
Orifice
NG4"
Orifice
Size
BTU
Size
(mm)
(mm)
0.55
3,000
0.85
0.65
5,800
0.70
8,400
0.95
14,000
1.75
1.14
20,000
2.15
LP11"
Orifice
BTU
Size
(mm)
3,000
0.55
1.1
5,700
0.7
1.3
8,700
0.8
13,000
1.05
19,000
1.22