Flame pattern

It may take approximately two hours of operation for the logs to achieve their full flame
pattern and glow. During the initial burning in period, some smoke and smell may be
experienced. The appliance should run on the high setting in a well ventilated room until
these dissipate. It is important to check the flame pattern during this time.
Abnormal flame pattern
Abnormal flame performance
and/or pattern can indicate a
problem with your fire, such as
blocked gas injectors, or that
the burn media has shifted from
when the fire was first installed.
There are some warning signs
that could indicate a problem.
-
Unusual smell from the
appliance
-
Continued difficulty or delay
in establishing a flame
-
Flame appears either very
short or very long
-
Flame only burns part way
across the burner
-
Severe soot building up on
the inside of the glass door
Important
It is the responsibility of the
installer to check that under
normal conditions of the
appliance, all flue gases are
exhausted to the outside
atmosphere, and that there is
no spillage of combustion gases
into the room.
If the appliance cannot be made
to perform correctly please
contact Rinnai.
Normal flame pattern
Abnormal flame pattern