Func.
Code
Description
H005
Motor speed constant, 1st motor
Motor proportional gain constant, factory set
H205
Motor speed constant, 2nd motor
Motor proportional gain constant, factory set
H006
Motor stabilization constant, 1st motor
H206
Motor stabilization constant, 2nd motor
H306
Motor stabilization constant, 3rd motor
H020
Motor constant R1, 1st motor
H220
Motor constant R1, 2nd motor
H021
Motor constant R2, 1st motor
H221
Motor constant R2, 2nd motor
H022
Motor constant L, 1st motor
H222
Motor constant L, 2nd motor
H023
Motor constant I
H223
Motor constant I
H024
Motor Constant J, 1st motor
H224
Motor constant J, 2nd motor
H030
Auto-tuned motor constant R1, 1st motor
H230
Auto-tuned motor constant R1, 2nd motor
H031
Auto-tuned motor constant R2, 1st motor
H231
Auto-tuned motor constant R2, 2nd motor
H032
Auto-tuned motor constant L, 1st motor
H232
Auto-tuned motor constant L, 2nd motor
H033
Auto-tuned motor constant I
H233
Auto-tuned motor constant I
H034
Auto-tuned motor constant J, 1st motor
H234
Auto constant J, 2nd motor
H050
PI proportional gain for 1st motor
H250
PI proportional gain for 2nd motor
H051
PI integral gain for 1st motor
H251
PI integral gain for 2nd motor
H052
P proportional gain setting for 1st motor
H252
P proportional gain setting for 2nd motor
H060
0Hz SLV limit for 1st motor
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Keypad
Name/
SRW OPE
, 1st motor
0
, 2nd motor
0
, 1st motor
0
, 2nd motor
0
Range and Settings
0.001 to 9.999, 10.00 to 80.00 (10.000 to
80.000)
0.001 to 9.999, 10.00 to 80.00 (10.000 to
80.000)
0. to 255. (factory set)
0. to 255. (factory set)
0. to 255. (factory set)
0.001 to 9.999, 10.00 to 65.53 (Ohms)
0.001 to 9.999, 10.00 to 65.53 (Ohms)
0.001 to 9.999, 10.00 to 65.53 (Ohms)
0.001 to 9.999, 10.00 to 65.53 (Ohms)
0.01 to 99.99, 100.0 - 655.3 (mH)
0.01 to 99.99, 100.0 - 655.3 (mH)
0.01 to 99.99, 100.0 - 655.3 (A)
0.01 to 99.99, 100.0 - 655.3 (A)
0.001 to 9.999, 10.00 to 99.99, 100.0 to
999.9, 1000 to 9999. (ratio, unit-less)
0.001 to 9.999, 10.00 to 99.99, 100.0 to
999.9, 1000 to 9999. (ratio, unit-less)
0.001 to 9.999, 10.00 to 65.53 (Ohms)
0.001 to 9.999, 10.00 to 65.53 (Ohms)
0.001 to 9.999, 10.00 to 65.53 (Ohms)
0.001 to 9.999, 10.00 to 65.53 (Ohms)
0.01 to 99.99, 100.0 to 655.3 (mH)
0.01 to 99.99, 100.0 to 655.3 (mH)
0.01 to 99.99, 100.0 to 655.3 (mH)
0.01 to 99.99, 100.0 to 655.3 (mH)
0.001 to 9.999, 10.00 to 99.99, 100.0 to
999.9, 1000 to 9999. (ratio, unit-less)
0.001 to 9.999, 10.00 to 99.99, 100.0 to
999.9, 1000 to 9999. (ratio, unit-less)
0.0 to 999.9, 1000.
0.0 to 999.9, 1000.
0.0 to 999.9, 1000.
0.0 to 999.9, 1000.
0.01 to 10.00
0.01 to 10.00
0.0 to 100.0
3–67
SJ700
Inverter
2
Defaults
Run
Mode
FEF2
FUF2
FF2
Edit
FE2
FU2
F2
Lo Hi
(EU)
(USA)
(Jpn)
✔ ✔
1.590
1.590
1.590
✔ ✔
1.590
1.590
1.590
✔ ✔
100.
100.
100.
✔ ✔
100.
100.
100.
✔ ✔
100.
100.
100.
✘ ✘
According to inverter
rating
✘ ✘
✘ ✘
✘ ✘
✘ ✘
According to inverter
rating
✘ ✘
✘ ✘
✘ ✘
✘ ✘
According to inverter
rating
✘ ✘
✘ ✘
According to inverter
rating
✘ ✘
✘ ✘
According to inverter
rating
✘ ✘
✘ ✘
According to inverter
rating
✘ ✘
✘ ✘
According to inverter
rating
✘ ✘
✘ ✘
According to inverter
rating
✘ ✘
✔ ✔
100.0
100.0
100.0
✔ ✔
100.0
100.0
100.0
✔ ✔
100.0
100.0
100.0
✔ ✔
100.0
100.0
100.0
✔ ✔
1.00
1.00
1.00
✔ ✔
1.00
1.00
1.00
✔ ✔
100.
100.
100.

Advertisement