FOR YOUR SAFETY, READ BEFORE LIGHTING.
IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE.
A. This appliance is equipped with an ignition
device which automatically lights the pilot.
Do not try to light the pilot by hand.
B. BEFORE LIGHTING, smell all around the
appliance area for gas. Be sure to smell next
to the floor because some gas is heavier than
air and will settle to the floor.
WHAT TO DO IF YOU SMELL GAS:
• Extinguish any open flame.
• Open windows.
• Do not light any appliance.
• Do not touch any electrical switches.
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone.
• If your gas supplier cannot be reached, call
the fire department.
1. STOP! Read the safety information above.
2. Set the thermostat to the lowest setting.
3. Set the Burner Control Switch to the "OFF"
position.
MODE
CONTROLS
4. Set the Pilot Mode switch to the IPI / DC
position for intermitant pilot and draw collar
functionality. See Operation Manual for
details.
Set the Pilot Mode switch to CPI for continu-
ous pilot functionality. Use this mode in the
event of a power outage.
5. This appliance is equipped with an ignition
device which automatically lights the pilot.
DO NOT try to light the pilot by hand.
TO TURN OFF GAS TO THE APPLIANCE:
1. Set the thermostat to the lowest setting.
2. Turn off all electric power to the appliance if
service is to be performed.
CAUTION:
Do not operate this appliance
with the glass removed, cracked or broken. Replace-
ment of the glass panel shall be done by a licensed
or qualified serviceperson.

LIGHTING INSTRUCTIONS

WARNING:
LIGHTING INSTRUCTIONS
6. Wait five (5) minutes to clear out any gas.
TSI
7. Set the Burner Control Switch to the "ON"
8. Set the Burner Control Switch to the "STAT"
9. Set the thermostat to the desired setting to
9.
C. Use only your hand to turn the gas control
knob. Never use tools. If the knob will not
turn by hand, do not try to repair it. Call a
qualified technician. Force or attempted
repair may result in a fire or explosion.
D. Do not use this appliance if any part has
been under water. Immediately call a
qualified service technician to inspect the
appliance and to replace any part of the
control system and any gas control which
has been under water
.
Then, smell for gas, including near the floor.
If you smell gas, STOP! Follow "B" in the safety
information above on this label. If you do not
smell gas, go to the next step.
position. In IPI mode, the pilot will light after
the flue has been pre-heated by the draw
collar - about 2 or 3 minutes.
position for thermostatic control.
light the burner.
If the appliance does not operate, follow the
instructions "To Turn Off Gas To Appliance", and
call your service technician or gas supplier.
3. Set the Burner Control Switch to the
"OFF" position.
4. Close control access door.
CAUTIONNER:
l'appareil si le panneau frontal en verre n'est pas
en place, est craqué ou brisé. Confiez le remplace-
ment du panneau à un technicien agrée.

139472_Rev_B 8.28.12

PILOT LIGHT
ASSEMBLY
Ne pas utiliser
31

Hide quick links: