Thank you for purchasing a Panasonic DECT Cell Station Unit.
Please read this manual carefully before using this product and save this manual for future use.
DECT Cell Station Unit
Model No.

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic KX-TDA0141

  • Page 1: Quick Installation Guide

    Quick Installation Guide DECT Cell Station Unit KX-TDA0141 Model No. KX-TDA0142 KX-TDA0158 Thank you for purchasing a Panasonic DECT Cell Station Unit. Please read this manual carefully before using this product and save this manual for future use.
  • Page 2: Kx-Tda0141

    Important Information Important Information SAVE THESE INSTRUCTIONS Safety Notices Please observe the safety notices in this manual in order to avoid danger to users or other people, and prevent damage to property. The notices are classified as follows, according to the severity of injury or damage: WARNING This notice means that misuse could result in death or serious injury.
  • Page 3 Important Information – Near devices that emit electromagnetic noise, such as radios or televisions. – Near devices that emit high-frequency noise, such as sewing machines or welders. • Do not stretch or bend the cables. Also, do not allow anything to rest on the cables. •...
  • Page 4: Kx-Tda0142

    Important Information Additional Information For users in the European Union only Information for Users on Collection and Disposal of Old Equipment and used Batteries These symbols on the products, packaging, and/or accompanying documents mean that used electrical and electronic products and batteries should not be mixed with general household waste.
  • Page 5: Quick Installation Guide

    Table of Contents Table of Contents 1 Overview ....................6 2 Procedure Overview ................10 3 Site Planning ..................12 4 Before Site Survey .................16 5 Site Survey Using the KX-TCA175/KX-TCA255/KX-TCA256/ KX-TCA275/KX-TCA355/KX-TD7590 .............22 6 After Site Survey ..................26 7 Connecting a Cell Station to the PBX ..........27 8 Wall Mounting ..................52 9 Troubleshooting ..................56 Quick Installation Guide...
  • Page 6: Overview

    1 Overview 1 Overview Names and Locations KX-TDA0158 Antennas CS ID Number (ID: xxxxxxxxxx) DIP Switch RJ45 Modular KX-TDA0141/KX-TDA0142 Antennas CS ID Number (ID: xxxxxxxxxx) RJ11 Modular DIP Switch LED Indications (KX-TDA0158) Indication Colour Description STATUS Green/Red CS status indication •...
  • Page 7 For more details about the Portable Station (PS), refer to the Operating Instructions of the PS. Maximum Number of CSs Supported by PBX Notice The CSs are for connection to specified Panasonic PBXs only. The following number of CSs can be supported by each PBX. Maximum Number...
  • Page 8: Required Distances Between Equipment

    1 Overview Maximum Number Connected via KX-TDA0158 KX-TDA0141 KX-TDA0142 • DHLC card KX-NCP500 • DLC card • DHLC card KX-NCP1000 • DLC card Required Distances between Equipment CAUTION Maintain the distances listed below between equipment in order to prevent noise, interference or the disconnection of a conversation.
  • Page 9 1 Overview Item Description Modulation Scheme GFSK Roll-off factor=0.5 50 % roll-off in the transmitter Data Coding for Modulator Differential Coding Voice Codec 32 kbps ADPCM (CCITT G.721) Transmission Output Average 10 mW Peak 250 mW If the suffix of your PBX model is BX, TW, or XE, the value is 1880 MHz to 1895 MHz. If the suffix of your PBX model is BX, TW, or XE, the value is 8.
  • Page 10: Procedure Overview

    2 Procedure Overview 2 Procedure Overview When connecting the wireless system, use extreme care in conducting the site survey. Site surveys can be conducted using the KX-TCA175/KX-TCA255/KX-TCA256/KX-TCA275/KX-TCA355/KX-TD7590 PS. An incorrectly performed site survey can result in poor service area, frequent noise, and disconnection of calls. 1.
  • Page 11 2 Procedure Overview Map the CS coverage area at radio signal strength levels "3" and "8". Make sure that adjacent CS coverage areas overlap where the radio signal strength level is "8" by at least 5 m. Make sure that the radio signal strength level is greater than "3" at any location within the service area required by the user.
  • Page 12: Site Planning

    3 Site Planning 3 Site Planning Choosing the best site for the CS requires careful planning and testing of essential areas. The best location may not always be convenient for installation. Read the following information before installing the unit. Understanding Radio Waves Characteristics of Radio Waves The transmission of radio waves and the CS coverage area depend on the structure and materials of the building.
  • Page 13 3 Site Planning Object Material Transmission Tendency Wall Concrete The thicker they are, the less radio waves penetrate them. Ferroconcrete Radio waves can penetrate them, but the more iron there is, the more radio waves are reflected. Window Glass Radio waves usually penetrate them. Glass with wire net Radio waves can penetrate them, but tend to be reflected.
  • Page 14 3 Site Planning CS Coverage Area The example below shows the size of the coverage area of 1 CS if it is installed in an area with no obstacles. Note Radio signal strength levels are measured during the site survey (refer to "5 Site Survey Using the KX-TCA175/KX-TCA255/KX-TCA256/KX-TCA275/KX-TCA355/KX-TD7590").
  • Page 15 3 Site Planning If 1 CS cannot cover the entire service area, install additional CSs as required. Overlap the coverage areas of adjacent CSs. Where CS coverage areas overlap, the PS will start call handover to the next CS if the signal from one CS becomes weak.
  • Page 16: Before Site Survey

    4 Before Site Survey 4 Before Site Survey Use the KX-TCA175/KX-TCA255/KX-TCA256/KX-TCA275/KX-TCA355/KX-TD7590 PS to conduct the site survey. Note Display prompts for the site survey are only available in English. Checking the CS ID Number Check the CS ID number label attached to the CS. If the CS ID number label is not attached to the CS, check the CS ID number using the Maintenance Console.
  • Page 17 4 Before Site Survey Using the KX-TD7590 To enter letters INT' CS No. CS ID No. Press 1, 9, and POWER 0 to 7 0 to 9 and A to F for more than 5 seconds. To the Desired CS No. To the initial display Note To clear the CS ID number assigned to the PS, follow the procedure below:...
  • Page 18 4 Before Site Survey Setting and Installing the CS Temporarily for Site Survey Switch the Radio Signal Test switch from OFF to ON. Set the channel number switches as desired. Set the Power Supply Select switch as desired (KX-TDA0158 only). KX-TDA0158 Radio Signal Test Switch Power Supply Select Switch...
  • Page 19 4 Before Site Survey KX-TDA0141/KX-TDA0142 DIP Switch Channel Number Switch Keep this switch at the default "OFF" position. Otherwise, the CS will not function. Radio Signal Test Switch Channel 0 Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 Channel 7 Channel 8 Channel 9 Note If more than 1 CS is in Radio Signal Test mode, each CS must have a unique channel number.
  • Page 20 4 Before Site Survey KX-TDA0158 KX-TDA0141/KX-TDA0142 RJ45 Modular RJ11 Modular Telephone Cord (PSJA1017Z) Telephone Cord Power Supply Adaptor Power Supply Adaptor (PSZZ1TDA0142) (PSZZ1TDA0142) RJ11 Modular RJ11 Modular To AC Adaptor (KX-A11)/ To AC Adaptor (KX-A11/KX-TCA1)/ Battery Box (PSZZTD142CE) Battery Box (PSZZTD142CE)
  • Page 21 4 Before Site Survey Install the CS temporarily for the site survey. Install the CS at least 2 m above the floor, and place the antennas so that they are pointing in directions that are 90 degrees apart (for antenna diversity), as follows: Note The illustration of the CS is based on the KX-TDA0158.
  • Page 22: Site Survey Using The Kx-Tca175/Kx-Tca255/Kx-Tca256 Kx-Tca275/Kx-Tca355/Kx-Td7590

    5 Site Survey Using the KX-TCA175/KX-TCA255/KX-TCA256/KX-TCA275/KX-TCA355/KX-TD7590 5 Site Survey Using the KX-TCA175/ KX-TCA255/KX-TCA256/KX-TCA275/ KX-TCA355/KX-TD7590 The PS has a Radio Signal Test mode that monitors the state of the radio link to the CS for site survey. In Radio Signal Test mode, the frame loss and signal strength of a synchronous slot, and the signal strength of the other slots can be measured when the PS is monitoring the CS.
  • Page 23 5 Site Survey Using the KX-TCA175/KX-TCA255/KX-TCA256/KX-TCA275/KX-TCA355/KX-TD7590 • The PS will not operate in normal mode if scan data is saved on it. For details on clearing scan data, refer to "Clearing the Stored Scan Data". Measure the error rate and the radio signal strength by moving towards and away from the CS. Note •...
  • Page 24 5 Site Survey Using the KX-TCA175/KX-TCA255/KX-TCA256/KX-TCA275/KX-TCA355/KX-TD7590 Repeat steps 1 and 2 for other CSs, and relocate the CSs when necessary. Overlap adjacent CS coverage areas where the radio signal strength level is "8" by 5 m to 10 m. Channel no. 0 Channel no.
  • Page 25 5 Site Survey Using the KX-TCA175/KX-TCA255/KX-TCA256/KX-TCA275/KX-TCA355/KX-TD7590 Referring to the Stored Scan Data Using the KX-TCA175/KX-TCA255/KX-TCA256/KX-TCA275/KX-TCA355 Log No. Press 1, 9, and POWER 0 to 9 for more than 2 seconds. To go to other slots To go to specific channel Channel No.
  • Page 26: After Site Survey

    Hold down the POWER button on the PS until the PS is turned OFF. Disconnect the CS from the AC adaptor/battery box or the PBX to stop supplying electricity. KX-TDA0158 KX-TDA0141/KX-TDA0142 Switch all DIP switches on the CS from ON to OFF. KX-TDA0158...
  • Page 27: Connecting A Cell Station To The Pbx

    7 Connecting a Cell Station to the PBX 7 Connecting a Cell Station to the PBX Connection Examples for KX-TDA15 Refer to the following examples to connect a CS to the PBX. KX-TDA0158 connecting to KX-TDA15 Super Hybrid Port Cable Maximum Distance ø...
  • Page 28 7 Connecting a Cell Station to the PBX Super Hybrid Ports (RJ45) Port No. Signal Name Pin No. CS (RJ45) Pin No. Signal Name Master Quick Installation Guide...
  • Page 29 7 Connecting a Cell Station to the PBX DLC8 card (RJ45) DLC8 Port No. Port No. Signal Name Pin No. CS 1 (RJ45) Signal Name Pin No. Master CS 2 (RJ45) Signal Name Pin No. Master Quick Installation Guide...
  • Page 30 7 Connecting a Cell Station to the PBX CS 1 (RJ45) DLC8 card (RJ11) Signal Name Pin No. Port No. Signal Name Pin No. Master CS 2 (RJ45) Signal Name Pin No. Master Accessories and User-supplied Items for the CS Accessories (included): Screws ´...
  • Page 31 7 Connecting a Cell Station to the PBX KX-TDA0141 connecting to KX-TDA15 Super Hybrid Port Cable Maximum Distance ø 0.4 mm: 222 m ø 0.5 mm: 347 m ø 0.6 mm: 500 m CAT 5: 347 m A Super Hybrid Port...
  • Page 32 7 Connecting a Cell Station to the PBX Connection Examples for KX-TDA30 Refer to the following examples to connect a CS to the PBX. KX-TDA0158 connecting to KX-TDA30 Super Hybrid Port Cable Maximum Distance ø 0.4 mm: 222 m ø 0.5 mm: 347 m ø...
  • Page 33 7 Connecting a Cell Station to the PBX Super Hybrid Ports or DLC4 card (RJ45) Port No. Signal Name Pin No. CS (RJ45) Pin No. Signal Name Master Super Hybrid Ports or DLC4 card (RJ11) Port No. Signal Name Pin No. CS (RJ45) Pin No.
  • Page 34 7 Connecting a Cell Station to the PBX DLC8 card (RJ45) DLC8 Port No. Port No. Signal Name Pin No. CS 1 (RJ45) Signal Name Pin No. Master CS 2 (RJ45) Signal Name Pin No. Master Quick Installation Guide...
  • Page 35 7 Connecting a Cell Station to the PBX CS 1 (RJ45) DLC8 card (RJ11) Signal Name Pin No. Port No. Signal Name Pin No. Master CS 2 (RJ45) Signal Name Pin No. Master Accessories and User-supplied Items for the CS Accessories (included): Screws ´...
  • Page 36 7 Connecting a Cell Station to the PBX KX-TDA0141 connecting to KX-TDA30 Super Hybrid Port Cable Maximum Distance ø 0.4 mm: 222 m ø 0.5 mm: 347 m ø 0.6 mm: 500 m CAT 5: 347 m A Super Hybrid Port,...
  • Page 37 7 Connecting a Cell Station to the PBX Connection Examples for KX-TDA100/KX-TDA200/KX-TDA600/KX-TDE100/ KX-TDE200/KX-TDE600 Refer to the following examples to connect a CS to the PBX. KX-TDA0142 connecting to KX-TDA100/KX-TDA200/KX-TDA600/KX-TDE100/KX-TDE200/ KX-TDE600 Note The illustration of the PBX is based on the KX-TDE200. CSIF8 Card Port 1 Cable...
  • Page 38 7 Connecting a Cell Station to the PBX KX-TDA0158 connecting to KX-TDA100/KX-TDA200/KX-TDA600/KX-TDE100/KX-TDE200/ KX-TDE600 Note The illustration of the PBX is based on the KX-TDE200. DHLC8 Card Cable Maximum Distance ø 0.4 mm: 222 m ø 0.5 mm: 347 m ø 0.6 mm: 500 m CAT 5: 347 m...
  • Page 39 Check the connection of CS and the PBX using the Maintenance Console. For information about how to view CS information using the Maintenance Console, refer to "Utility—CS Information" in the PC Programming Manual for your PBX. KX-TDA0141 connecting to KX-TDA100/KX-TDA200/KX-TDA600/KX-TDE100/KX-TDE200/ KX-TDE600 Note The illustration of the PBX is based on the KX-TDE200.
  • Page 40 7 Connecting a Cell Station to the PBX Connection Examples for KX-NCP500/KX-NCP1000 Refer to the following examples to connect a CS to the PBX. KX-TDA0158 connecting to KX-NCP500/KX-NCP1000 Note The illustration of the PBX is based on the KX-NCP500. DHLC4 Card Cable Maximum Distance ø...
  • Page 41 7 Connecting a Cell Station to the PBX DHLC4 card (RJ45) Pin No. Signal Name Port No. CS 1 (RJ45) Signal Name Pin No. Master Quick Installation Guide...
  • Page 42 7 Connecting a Cell Station to the PBX DLC8/DLC16 card (RJ45) Pin No. Signal Name Port No. DLC8 Port No.: 1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 DLC16 CS 1 (RJ45) Pin No. Signal Name Master CS 2 (RJ45)
  • Page 43 Check the connection of CS and the PBX using the Maintenance Console. For information about how to view CS information using the Maintenance Console, refer to "Utility—CS Information" in the PC Programming Manual for your PBX. KX-TDA0141 connecting to KX-NCP500/KX-NCP1000 Note The illustration of the PBX is based on the KX-NCP500.
  • Page 44 7 Connecting a Cell Station to the PBX Connecting the CS Connect the cable from the PBX to the CS. KX-TDA0158 KX-TDA0141/KX-TDA0142 RJ45 Modular RJ11 Modular To PBX To PBX Pass the cable through the groove of the CS (in any direction depending on your preference).
  • Page 45 7 Connecting a Cell Station to the PBX For the KX-TDA0142 User only: Wrap the cable once around the ferrite core. Then close the case of the ferrite core. To PBX Note If you need to open the ferrite core, use a flathead screwdriver to unlatch the case of the ferrite core. Registering the PS The PS must be registered to the PBX before it can be used.
  • Page 46 7 Connecting a Cell Station to the PBX Entering the System Programming Mode PT (Administrator Level) System Password for Administrator— Programming No. for PT Programming PROGRAM/ PAUSE 1234 3 digits Note means default value throughout this section. Setting the Personal Identification Number (PIN) for PS Registration To prevent registering the PS to a wrong PBX, a PIN for PS registration can be set to the PBX.
  • Page 47 7 Connecting a Cell Station to the PBX Using the KX-TCA155/KX-TCA255/KX-TCA256/KX-TCA355 Press POWER Select Select for 2 seconds. "Setting Handset". "Display Option". Select Select the desired "Select Language". language. Using the KX-TD7590 SELECT SELECT Press POWER Select Select for 5 seconds. "DISPLAY SETTING".
  • Page 48 7 Connecting a Cell Station to the PBX When the PS has already been registered to another PBX One PS can be registered to a maximum of 4 different PBXs. Press POWER Select Select for 2 seconds. "Setting Handset". "System Option". If required System Lock Password 4 digits...
  • Page 49 7 Connecting a Cell Station to the PBX CAUTION To avoid unauthorised access and possible abuse of the PBX, we strongly recommend: Keeping the password secret. Changing your password regularly. Selecting a complex, random password that cannot be easily guessed. Press POWER for 5 seconds.
  • Page 50 7 Connecting a Cell Station to the PBX PS Termination Confirm the following before cancelling the PS registration: • The PS is turned on. • The PS is within range. [691] PS No. 001 to max. no. ENTER ENTER of PSs (3 digits) If "Rejected"...
  • Page 51 7 Connecting a Cell Station to the PBX Using the KX-TD7590 SELECT Press POWER Select "DECT- for 5 seconds. SYS SETTING". If required SELECT System Lock Password Select the Select "CANCEL 4 digits desired item. DECT-SYS". SELECT SELECT C.Tone Select "YES". Using the KX-TD7580 Press POWER Select...
  • Page 52: Wall Mounting

    8 Wall Mounting 8 Wall Mounting Mounting the KX-TDA0158 WARNING • Make sure that the wall that the unit will be attached to is strong enough to support the unit (approx. 310 g). If not, it is necessary for the wall to be reinforced. •...
  • Page 53 8 Wall Mounting Place the antennas so that they are pointing in directions that are 90 degrees apart (for antenna diversity), as follows: 45º 90º 45º Reference for Wall Mounting (KX-TDA0158) Please copy this page and use as a reference for wall mounting. Install a screw here.
  • Page 54 Do not bundle cables that are connected to the CS with the AC power cords of machines located nearby. • Make sure the cables are securely fastened to the wall. Place the reference for wall mounting (KX-TDA0141/KX-TDA0142) on the wall to mark the 2 screw positions. Install the 2 screws and washers (included) into the wall. Note •...
  • Page 55 Place the antennas so that they are pointing in directions that are 90 degrees apart (for antenna diversity), as follows: 45º 90º 45º Reference for Wall Mounting (KX-TDA0141/KX-TDA0142) Please copy this page and use as a reference for wall mounting. Install a screw here. 71 mm Install a screw here.
  • Page 56: Troubleshooting

    9 Troubleshooting 9 Troubleshooting PROBLEM PROBABLE CAUSE SOLUTION • • • The LED of the CS does not The optional service card is Install the card properly. change to Green ON. not working. • • CS is not connected Make sure that the cable is connected properly.
  • Page 57 9 Troubleshooting PROBLEM PROBABLE CAUSE SOLUTION • • • Noise is frequent while Call handover is not Locate the CS properly (refer to "5 Site using the PS. working. Survey Using the KX-TCA175/ • • KX-TCA255/KX-TCA256/KX-TCA275/ Conversations disconnect PS is out of CS coverage KX-TCA355/KX-TD7590").
  • Page 58 Copyright: This material is copyrighted by Panasonic Communications Co., Ltd., and may be reproduced for internal use only. All other reproduction, in whole or in part, is prohibited without the written consent of Panasonic Communications Co., Ltd. Panasonic Communications Co., Ltd. 2009...