Check Gas Type; Clearances To Combustibles - Desa Amity Owner's Operation And Installation Manual

Unvented (vent-free) gas stove heater
Table of Contents

Advertisement

INSTALLATION
Continued
CAUTION: This heater creates warm air currents.
These currents move heat to wall surfaces next to
heater. Installing heater next to vinyl or cloth wall
coverings or operating heater where impurities (such
as, but not limited to, tobacco smoke, aromatic
candles, cleaning fluids, oil or kerosene lamps, etc.)
in the air exist, may discolor walls or cause odors.
IMPORTANT: Vent-free heaters add moisture to the air. Although
this is beneficial, installing heater in rooms without enough venti-
lation air may cause mildew to form from too much moisture. See
Air for Combustion and Ventilation, pages 4 through 6.

CHECK GAS TYPE

Use the correct gas type (natural or propane/LP) for your unit. If
your gas supply is not correct, do not install heater. Call dealer where
you bought fireplace for proper type fireplace.

CLEARANCES TO COMBUSTIBLES

(Vent-Free Operation Only)
WARNING: Maintain the minimum clearances. If
you can, provide greater clearances from floor, ceil-
ing, and adjoining side and back walls.
Carefully follow the instructions below. This stove is a freestanding
unit designed to set directly on the floor. IMPORTANT: You must
maintain minimum wall and ceiling clearances during installation.
The minimum clearances are shown in Figure 4. Measure from
outermost point of stove top.
Minimum Wall and Ceiling Clearances (see Figure 4)
A. Clearances from outermost point of stove top to any combus-
tible side wall should not be less than 12 inches.
B. Clearances from outermost point of stove top to any combus-
tible back wall should not be less than 6 inches (includes cor-
ner installations).
C. Clearances from the stove top to the ceiling should not be less
than 48 inches.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
111162-01B
Clearances to Combustibles
12"
Side Wall
Minimum
Back Wall
12
"
Minimum
Side Wall
Top View
Corner
Wall
6
"
Minimum
Wall
6
"
Minimum
Front of
Stove Unit
Side View
Figure 4 - Minimum Clearance to Walls and Ceiling (Stove May
Vary Depending on Model)
INSTALLATION
Check Gas Type
Ceiling
48"
Minimum
Front View
12"
Side Wall
Minimum
6
"
Minimum
12
"
Minimum
Side Wall
Front of
Stove Unit
Ceiling
48"
Minimum
6"
Minimum
Floor
7 7
Back Wall