2-6: LOADING MOTOR/WORM (Refer to Fig. 2-6-A)
Remove the screw 1.
1.
2.
Remove the Loading Motor.
3.
Remove the Worm.
Main Chassis
• Screw Torque: 3 ± 0.5kgf•cm
NOTE
1.
In case of the Worm installation, check if the value of
the Fig. 2-6-B is correct.
2.
In case of the Loading Motor installation, slacken the
wire as shown Fig. 2-6-C.
3.
When installing the wires between Capstan DD Unit
and Loading Motor, connect them correctly as shown
Fig. 2-6-D.
Safety surface for pressing
of the insert.
Slacken the wire.
Loading Motor
Pink
Loading Motor
-
+
White
DISASSEMBLY INSTRUCTIONS
Loading Motor
Worm
1
Fig. 2-6-A
19.2 ± 0.1mm
Fig. 2-6-B
Fig. 2-6-C
Capstan DD Unit
L2
L1
Fig. 2-6-D
2-7: TENSION ASS'Y (Refer to Fig. 2-7-B)
1.
Turn the Pinch Roller Cam clockwise so that the
Tension Holder hook is set to the position of Fig. 2-7-A
to move the Tension Arm Ass'y.
2.
Remove the Tension Spring.
Unlock the 2 supports 1 and remove the Tension
3.
Band.
Unlock the support 2 and remove the Tension Arm
4.
Ass'y.
Unlock the support 3 and remove the Tension
5.
Connect.
Float the hook 4 and turn it clockwise then remove the
6.
Tension Holder.
Tension Arm Ass'y
Tension Connect
Tension Spring
NOTE
1.
In case of the Tension Band installation, note the
direction of the installation. (Refer to Fig. 2-7-C)
2.
In case of the Tension Band installation, install correctly
as Fig. 2-7-D.
3.
In case of the Tension Connect installation, install as
the circled section of Fig. 2-7-E.
Tension Connect
[OK]
[NG]
Tension Connect
B2-2
1
1
Tension Band
3
Tension Arm Ass'y
Tension Holder
2
4
Tension Band
Tension Connect
Tension Band
Tension Connect
Tension Band
Main Chassis
Fig. 2-7-A
Fig. 2-7-B
Fig. 2-7-C
Fig. 2-7-D
Fig. 2-7-E