1.2.1 Perform a Cold Start

This section describes the process for starting the system for the first time or starting a system that
requires the customer data be deleted.
System software is loaded from flash memory, and the customer data is deleted
from RAM memory.
If Expansion KSU(s) are installed, turn the power on/off in the order of Expan-
sion 2 KSU, Expansion 1 KSU and then Main KSU.
To perform a Cold Start;
1. Set the power switch to off position.
2. Open the Sub-Cover on the Main KSU and identify the LOAD button (S1) location on the CPU
card.
Sub-Cover
Tab
3. Once the system has powered off, push in and hold the LOAD button (S1).
If Expansion KSU(s) are installed, the Power Switch must be ON at Expansion
KSU(s).
4. Turn the power switch ON at the Main KSU.
3-2

Figure 3-2 Power Switch Location

Tab

Figure 3-3 Load Button (S1) Location

CPU card
S1
< Front view >
System Start Up
ISSUE 1.0