SL1100
1.2.1 Perform a Cold Start
This section describes the process for starting the system for the first time or starting a system that
requires the customer data be deleted.
System software is loaded from flash memory, and the customer data is deleted
from RAM memory.
If Expansion KSU(s) are installed, turn the power on/off in the order of
Expansion 3 KSU (V3.5 or higher), Expansion 2 KSU, Expansion 1 KSU and
then Main KSU.
To perform a Cold Start;
1.
Set the power switch to off position.
2.
Open the Sub-Cover on the Main KSU and identify the LOAD button (S1) location on the CPU
card.
3-2
Figure 3-2 Power Switch Location
Sub-Cover
Tab
Figure 3-3 Load Button (S1) Location
Tab
CPU card
< Front view >
ISSUE 5.0
S1
System Start Up