Replacing Switch And/Or Head Tube - Hobart Handler 135 Owner's Manual

Handler 135; handler 175; h-10 gun
Table of Contents

Advertisement

5-7. Replacing Switch And/Or Head Tube

1
Remove handle
locking nut.
4
Secure head
tube in vice.
6
Hand-tighten head tube into cable connector.
Tools Needed:
19 mm
Y Turn Off welding power source
/wire feeder and disconnect gun.
5
Loosen jam nut.
Remove from vice
and turn head tube
out by hand.
8
Remove from vice. Reposition handle and install
switch housing. Secure with handle locking nut.
3
Slide handle.
2
Remove switch housing. Install new switch and
connect leads (polarity is not important). Reas-
semble in reverse order. If replacing head tube,
continue to end of figure.
7
Place head tube in vice and tighten until
nuts are tight.
Ref. ST-800 795-C