Gas Connection; Electrical Connection - Indesit IPG 640 S GB Operating Instructions Manual

Table of Contents

Advertisement

GB
Hooking position
for top H=40mm
! Use the hooks contained in the "accessory pack".
• Where the hob is not installed over a built-in oven, a
wooden panel must be installed as insulation. This must
be placed at a minimum distance of 20 mm from the lower
part of the hob.
Ventilation
To ensure adequate ventilation, the back panel of the cabinet
must be removed. It is advisable to install the oven so that it
rests on two strips of wood, or on a completely flat surface
with an opening of at least 45 x 560 mm (see diagrams).
! The hob can only be installed above built-in ovens with a
cooling ventilation system.

Electrical connection

! THIS APPLIANCE MUST BE EARTHED.
The hob is designed to work with alternating current, the
supply voltage and frequency indicated on the rating plate
(situated under the hob). Make sure that the local supply
voltage corresponds to the voltage indicated on the rating
plate.
Connecting the supply cable to the mains electricity
supply
For models supplied without a plug, fit a standard plug
suitable for the load indicated on the rating plate, onto a
cable and connect to a suitable socket. To connect direct
to the mains supply, a double pole switch with a contact
separation of at least 3mm suitable for the load and
complying with current standards and regulations must be
fitted between the appliance and the mains supply outlet.
The green-yellow earth wire must not be interrupted by
the switch.
The supply cable must be positioned so that no part of it
reaches a temperature of 50°C above room temperature.
For installation above a built-under oven, the hob and the
oven must be connected separately to the electricity supply,
both for safetly reasons and for easy removal of the oven
PLEASE PHONE US TO REGISTER YOUR APPLIANCE AND ACTIVATE YOUR PARTS GUARANTEE ON 08448 24 24 24
6
Front
Back
for repair, maintenance etc.
DO NOT use adapters as they could cause overheating
or burning.
Before connecting to the power supply, make sure that:
• the limiter switch and the domestic system can withstand
the load from the appliance (see rating plate).
• the supply system is efficiently earthed according to
standards and laws in force.
• the socket or double-pole switch are easily accessible
when the appliance is installed.
! The wires in the mains lead are coloured in accordance
with the following code:
Green & Yellow - Earth
Blue
- Neutral
Brown
- Live
As the colours of the wires in the mains lead may not
correspond with the coloured markings identifying the
terminals in your plug, proceed as follows:
Connect the Green & Yellow wire to terminal marked "E" or
or coloured Green or Green & Yellow.
Connect the Brown wire to the terminal marked "L" or
coloured Red or Brown.
Connect the Blue wire to the terminal marked "N" or coloured
Black or Blue.
FAILURE TO OBSERVE THE ACCIDENT-PREVENTION
REGULATIONS RELIEVES THE MANUFACTURER OF
ALL LIABILITY.
Replacing the cable
Use a rubber cable of the type H05RR-F with a suitable
cross section 3 x 0.75 mm².
The yellow-green earth wire must be 2-3 cm longer than
the other wires.

Gas connection

The appliance should be connected to the main gas supply
or to a gas cylinder in compliance with current national
regulations. Before carrying out the connection, make sure
the cooker is compatible with the gas supply you wish to
use. If this is not the case, follow the instructions indicated
in the paragraph "Adapting to different types of gas."
When using liquid gas from a cylinder, install a pressure
regulator which complies with current national regulations.
! Check that the pressure of the gas supply is consistent
with the values indicated in Table 1 ("Burner and nozzle
specifications"). This will ensure the safe operation and
longevity of your appliance while maintaining efficient
energy consumption.
Connection with a rigid pipe (copper or steel)
! Connection to the gas system must be carried out in such a
way as not to place any strain of any kind on the appliance.
There is an adjustable L-shaped pipe fitting on the appliance
supply ramp and this is fitted with a seal in order to prevent
leaks. The seal must always be replaced after rotating the
pipe fitting (seal provided with appliance). The gas supply
pipe fitting is a threaded 1/2 gas cylindrical male attachment.

Advertisement

Table of Contents
loading

Table of Contents