Satellite Terminal System
Terminal Mode Commands
Reference
Command
Current Faults
Response
ADAP
Command
2 and 4 Watt
Response
SSPAs
Current Faults
LNB
Command
Current Faults
Response
AGC
Command
Current Faults
Response
Common
Command
Equipment
Response
Current Faults
Clear
Command
Stored Faults
Response
Up Converter
Command
Stored Faults
Response
Down Converter
Command
Stored Faults
Response
Reference Stored
Command
Faults
Response
<add/RS_'cr'
>add/RS_'cr'
REF_yyy'cr'
72MHZ_xxx'cr'
OSC_zzz'cr'
SFLT_#'cr''lf']
<add/HS_'cr'
>add/HS_'cr'
RF_yyy'cr'
HPA_xxx'cr'
BV1_xxx'cr'
+9.75V_xxx'cr'
-5V_xxx'cr'
PROG_xxx'cr'
SFLT_#'cr''lf']
<add/LS_'cr'
>add/LS_'cr'
LNA_xxx'cr'
SFLT_#'cr''lf']
<add/AGS_'cr'
>add/AGS_'cr'
EIP_xxx'cr'
IIP_xxx'cr'
LOOP_xxx'cr'
SFLT_#'cr''lf']
<add/CES_'cr'
>add/CES_'cr'
M&C_xxx'cr'
-7V_xxx'cr'
+7V_xxx'cr'
+12V_xxx'cr'
+17V_xxx'cr'
SFLT_#'cr''lf']
<add/CLSF_'cr'
>add/CLSF_'cr''lf']
<add/USF_#'cr'
>add/USF_#'cr'
RF_yyy'cr'
UC_xxx'cr'
SSYN_xxx'cr'
KSYN_xxx'cr'
LSSYN_xxx'cr'
LKSYN_xxx'cr'
PROG_xxx'cr''lf']
<add/DSF_#'cr'
Where xxx = OK or FLT, #= stored fault loaction (0 to 9), DC =
>add/DSF_#'cr'
downconverter,
DC_xxx'cr'
LSYN = Ku-Band synthesizer lock detect, KSYN = Ku-band
LSYN_xxx'cr'
synthesizer lock detect, LLSYN = latched Ku-Band synthesizer
KSYN_xxx'cr'
lock detect, LKSYN = latched Ku-band synthesizer lock detect,
LLSYN_xxx'cr'
inter processor communications
LKSYN_xxx'cr'
PROG_xxx'cr''lf']
<add/RSF_#'cr'
Where yyy = INT, xxx = OK or FLT, zzz = WARM or COLD, # =
>add/RSF_#'cr'
stored fault location, 72MHZ = 72 MHz lock detect, LOCK and
REF_yyy'cr'
PHASE_N and RANGE refer to an external reference
72MHZ_xxx'cr'
OSC_zzz'cr''lf']
7–9
Where yyy = INT, xxx = OK or FLT, zzz = WARM or COLD, # =
number of stored faults, 72MHZ = 72 MHz lock detect, LOCK and
PHASE_N and RANGE refer to an external reference
Where yyy = ON or OFF, xxx = OK or FLT, BV1 = bias voltage
#1, PROG = inter processor communications, # = number of stored
faults (1 to 10)
Where xxx = OK or FLT, # = number of stored faults (1 to 10)
Where xxx = OK or FLT, # = number of stored faults (1 to 10),
EIP = excessive input power, IIP = insufficient input power,
LOOP = loop converge
Where xxx = OK or FLT, # = number of stored faults (1 to 10)
Clears all stored faults in all locations
Where # = stored fault location (0 to 9), yyy = ON or OFF, xxx =
OK or FLT, ( 1 to 10), RF = RF output, UC = upconverter,
SSYN = S-band synthesizer lock detect, KSYN = Ku-band
synthesizer lock detect, LSSYN = latched S-band synthesizer lock
detect, LKSYN = latched Ku-band synthesizer lock detect, inter
processor communications
Revision 2
MN/KST2000L.IOM