Kenwood TK-8180 Service Manual Supplement page 25

Uhf fm transceiver
Hide thumbs Also See for TK-8180:
Table of Contents

Advertisement

Receiver Section (K market model skips adjustment of Wide 4k)
Item
Condition
1. Sensitivity
1) Adj item : [SENS1]
adjust
Adjust : [✳✳✳]
2) Adj item : [L SENS1] →
[L' SENS1] → [C SENS1] → Oscilloscope
[H' SENS1] → [H SENS1]
Adjust : [✳✳✳]
2. Sensitivity
[Panel test mode]
check
1) CH-Sig : 1-1
SSG output
Wide 5k : –116dBm (0.35µV)
(MOD : 1kHz/± 3kHz)
Narrow : –116dBm (0.35µV)
(MOD : 1kHz/± 1.5kHz)
3. Squelch
1) Adj item : [n SQL]
(Preset)
Adjust : [✳✳✳]
adjust
SSG output : 12dB SINAD level
• Narrow
(MOD : 1kHz/± 1.5kHz)
2) Adj item : [nL SQL] →
[nC SQL] → [nH SQL]
Adjust : [✳✳✳]
• Wide 4k
3) Adj item : [s SQL]
Adjust : [✳✳✳]
SSG output : 12dB SINAD level
(MOD : 1kHz/± 2.4kHz)
4) Adj item : [sL SQL] →
[sC SQL] → [sH SQL]
Adjust : [✳✳✳]
• Wide 5k
5) Adj item : [w SQL]
Adjust : [✳✳✳]
SSG output : 12dB SINAD level
(MOD : 1kHz/± 3.0kHz)
6) Adj item : [wL SQL] →
[wC SQL] → [wH SQL]
Adjust : [✳✳✳]
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
SSG
Rear
ANT
Front
panel
panel
AF VTVM
EXT. SP
TK-8180
Adjustment
Parts
Method
[ ],[ ] Enter the following
Note : After replacing the
adjustment values
EEPROM (IC401) aline
to the transceiver
sensitivity.
by pressing [ ] and
[ ] keys.
[L SENS1]
: 70 K 95 K2
[L' SENS1]
: 90 K 123 K2
[C SENS1]
: 115 K 151 K2
[H' SENS1]
: 138 K 173 K2
[H SENS1]
: 164 K 195 K2
After setting the
adjustment value,
press [B] key.
The adjustment
value will be stored
in memory.
Check
12dB SINAD or more
After input signal
After adjusting SQL, check
from SSG, press [B] SQL open/close.
key. That numeric
SSG 12dB SINAD level + 4dB
will be stored in
memory.
SSG 12dB SINAD level – 6dB
[nC SQL] MOD 1kHz/± 1.5kHz
[sC SQL] MOD 1kHz/±2.4kHz
[wC SQL] MOD 1kHz/± 3.0kHz
Specifications/Remarks