Adjust Water-To-Syrup Ratio

1. Remove valve front cover and install syrup diversion assembly in
place of nozzle.
Water Flow
Adjuster on
Left
2.
Adjust carbonated water !ow to the desired rate (such as 2.50 oz. / sec.)
(70g / sec.).
T
o increase !ow turn clockwise.
3. Adjust the syrup-to-water ratio of each valve using the syrup adjuster
on the left side of each valve. Hold cup under valve and dispense
beverage for a speci"c time (such as 4 seconds).
Adjusting Flow Rates
Flow rates of the water and syrup are adjusted based on the desired ratio.
For example: if the desired ratio is 5:1, then the !ow rate of the water is 5
times that of the syrup.
If the desired "nished drink !ow rate is 3.0 ounces per second, then the
water !ow rate is 2.5 oz./sec. (70 g / sec.) and the syrup !ow rate is
0.5 oz./sec. (14 g / sec.) (The water at 2.5 oz./sec. (70 g / sec.) is "ve times
the 0.5 oz./sec. (14 g / sec.) syrup !ow rate.)
Syrup
Adjuster on
Right
T
urn the adjuster 1/4 of a turn at a time and recheck the !o
Syrup
Diversion
Tube
Ratio Cup