Ice/Beverage Dispenser Installation Manual
A
-
DJUST WATER
TO
1. Remove the valve cover and install syrup separator over the diffuser and through the nozzle.
2. Hold cup under the valve and beverage for a specific time ( i.e. 2 seconds)
3. NOTE: water and syrup must be cold before checking the ratios.
4. Adjust carbonated water flow to the desired rate (such as 90 to 110 ml(3 to 3.75 oz) per second). Turn the flow
adjuster 1/4 of a turn at a time and recheck the flow. Increase reading turn clockwise.
5. Set a syrup flow adjuster to get the desired ration.
6. Test the valve and adjust until a consistent ratio is delivered three consecutive times.
7. Repeat procedure for other valves.
Publication Number: 620917902INS
-
SYRUP RATIO
- 5 -
© 2004-2010, IMI Cornelius Inc.