Adjusting Dispensing Valves Water Flow Rate - Cornelius VANTAGE Installation Manual

Hide thumbs Also See for VANTAGE:
Table of Contents

Advertisement

A
D
DJUSTING
ISPENSING
(see Figure 3)
1. Remove cover from the dispensing valve by lifting the front cover up 1/4 inch and pulling forward.
2. Install syrup diversion tube assembly on the dispensing valve by pushing rubber end of the syrup diversion
tube onto the syrup outlet of the inner nozzle.
3. Measure the water flow rate by dispensing water into a graduated cup for a set period of time.
NOTE: Adjusting screw stops are built into the valve to prevent leakage when the screws are
adjusted too far clockwise. Stop adjusting clockwise when turning resistance increases. Turn the
screw counterclockwise 1–1/2 turns after the stop are contacted.
4. Turn the water flow regulator adjusting screw to the left (counterclockwise) to decrease the water flow rate or
turn the adjusting screw to the right (clockwise) to increase the water flow rate, then recheck the flow rate.
Adjustments should be no more than 1/4 turn at a time.
5. Remove syrup diversion tube from the dispensing valve, then install cover on the dispensing valve.
© 2003-2014, Cornelius Inc.
V
W
F
ALVES
ATER
Figure 3. UF-1 Dispensing Valve
- 6 -
Vantage Installation Manual
R
LOW
ATE
Publication Number: 312031005INS