Honeywell MicroMAX Pro User & Maintenance Manual page 75

Multi-gas monitors
Table of Contents

Advertisement

MAN-MAXPRO
REV. B.0.
(K)
Sensor
Combustible (% LEL)
Combustible (% by vol.)
Carbon monoxide (CO)
Hydrogen sulfide (H2S)
Sulfur dioxide (SO2)
Phosphine (PH3)
Ammonia (NH3)
Chlorine (CL2)
Chlorine Dioxide (CLO2)
Combo-Tox (CO\H2S)
Nitrogen Dioxide (NO2)
Hydrogen Cyanide (HCN)
(L)
User selectable languages:
(M)
GAS
Oxygen
Combustible (LEL)
Carbon Monoxide
Hydrogen Sulfide
Sulfur Dioxide
Phosphine
Hydrogen Cyanide
Note: Consult factory for response time data for other gases.
APPENDIX A - SPECIFICATIONS
User Programmable Calibration Gas Levels
Increment
5% LEL
0.5%
5PPM
5PPM
5PPM
0.1PPM
5PPM
1PPM
1PPM
5PPM
1.0PPM
1PPM
Voice Messaging
English
Spanish
French
German
Response Time Data
Range
5-60% LEL
1.0-3.0%
50-300PPM
5-25PPM
5-20PPM
1.0-5.0PPM
10-50PPM
1-10PPM
1-5PPM
50-300PPM CO
2.0-10.0PPM
5-20PPM
RESPONSE TIME (T90)
75
Defaults
50% LEL
2.5% CH4
50PPM
25PPM
10PPM
5.0PPM
25PPM
10PPM
1PPM
50PPM CO
10.0PPM
10PPM
SECONDS
10
20
08
15
05
23
21

Advertisement