Honeywell MicroMAX Pro User & Maintenance Manual page 73

Multi-gas monitors
Table of Contents

Advertisement

MAN-MAXPRO
REV. B.0.
(G)
Sensor
Combustible (LEL)
Combustible (% by vol.) *
Oxygen (O2)
Carbon Monoxide (CO)
Hydrogen Sulfide (H2S)
Sulfur Dioxide (SO2)
Phosphine (PH3)
Ammonia (NH3)
Chlorine (CL2)
Chlorine Dioxide (CLO2)
Combo-Tox (CO/H2S)
Nitrogen Dioxide (NO2)
Hydrogen Cyanide (HCN)
* The % by volume sensor is for monitoring methane, natural gas & hydrogen
only
(H)
APPENDIX A - SPECIFICATIONS
Gas Ranges and Resolution
If instrument is used in oxygen environments below 10%,
the displayed LEL reading will be lower than actual value.
In this event, use of dilution tube, part number MAX-DT, is
recommended.
Repeatability
+/- 2%
Instrument
Resolution
Range
0-100% LEL
1%LEL
0-100% CH4
0.1%(0-9.9%), 1%(10-100%)
0-40%
0.1%
0-999PPM
1PPM
0-500PPM
1PPM
0-20PPM
0.1PPM
0-20PPM
0.1PPM
0-500PPM
1PPM
0-20PPM
0.1PPM
0-9.9PPM
0.1PPM
0-500PPM
1PPM
0-50PPM
0.1PPM
0-50PPM
1PPM
WARNING
73

Advertisement

Table of Contents
loading

Table of Contents