9.2.1.5
Software configuration
The UFM delivery set includes the "Recovery Tool CD" to setup the ESXi
configuration. Proceed as follows:
Ê Switch on the server.
Ê Right after switching on the server, insert the "Recovery Tool CD" into the
DVD drive and close the drive tray.
Ê The server should now boot from the "Recovery Tool CD".
Ê Follow the on-screen instructions.
9.2.2
Removing the UFM board
Field Replaceable Units (FRU)
Average task duration: 5 minutes
9.2.2.1
Required tools
Preliminary and concluding steps: tool-less
●
Main steps:
●
– Phillips PH1 / (+) No. 1 screw driver
9.2.2.2
Preliminary steps
Perform the following procedures:
"Disabling SVOM boot watchdog functionality" on page 65
Ê
Ê Locate the desired server with the ID button.
"Shutting down the server node" on page 43
Ê
Ê If applicable, remove all external cables from the server node.
"Removing the server node from the server enclosure" on page 44
Ê
CX270 S2
Upgrade and Maintenance Manual
System board and components
273