Table 1. Fibre Channel switch-module specifications (continued)
Switch maintainability:
v Diagnosis: Power-on
self-test (POST) is
performed on all
functional components
except the SFP module.
Port operational tests
include internal, external,
and online tests.
v User interface:
Light-emitting diode
(LED) indicators.
Fabric management:
v Management methods:
– Web interface through
Advanced Web Tools
– Command-line
interface (CLI) through
Telnet program
– Application program
interface (API)
v Brocade Fabric Manager
for Eserver Advanced
Feature Options:
Provides Java
-based
application program to
help manage the storage
area network (SAN) fabric
v Management information
base (MIB)
v Switch simple network
management protocol
(SNMP) agent:
Enables a network
management workstation
to receive configuration
values, traffic information,
and Fibre Channel failure
data through SNMP and
the Ethernet interface
Dimensions:
v Width: 112 mm (4.41 in.)
v Height: 29 mm (1.14 in.)
v Depth: 260.3 mm
(10.25 in.)
v Weight: Approximately
0.91 kg (2 lb)
Environmental:
v Temperature and altitude:
– Operating:
- 10°C to 52°C
(50°F to 125.6°F) at
an altitude of
0 to 914 m
(0 to 3000 ft)
- 10°C to 49°C
(50°F to 120.2°F) at
an altitude of
0 to 3000 m
(0 to 10 000 ft)
– Non-operating:
-40°C to 65°C
(-40°F to 149°F) at an
altitude of
0 to 12 000 m
(0 to 39 370 ft)
v Humidity:
– Operating: 8% to 80%,
noncondensing
– Non-operating: 5% to
80%, noncondensing
Chapter 1. The Brocade 4 Gb SAN switch module
Switch-module regulatory
certifications:
v Electrical requirements:
– Power source loading:
3.75 amps maximum at
12 V dc
– Approximate heat
output in British
thermal units (Btu) per
hour: 85.3 Btu (25
watts)
– Operating voltage:
12 V dc
– Circuit protection:
Internally fused with
over-current protection
v Safety standards:
– As a listed accessory
by UL (USA)
– As a component by
TUV
5