The GPIO card has the following menu configurable features and can be tailored to your
application.
GPIO PORT
GPIO DEVICE
DISABLED
APPLICATOR
APPLICATOR2
BARCODE
VERIFIER
START OF PRINT
LOW PULSE
HIGH PULSE
ACTIVE LOW
ACTIVE HIGH
EDGE
END OF PRINT
LOW PULSE
HIGH PULSE
ACTIVE LOW
ACTIVE HIGH
RIBBON LOW
ACTIVE LOW
ACTIVE HIGH
SLEW ENABLE
STANDARD
LOW PULSE
HIGH PULSE
ACTIVE LOW
ACTIVE HIGH
Err On Pause
(App2)
ENABLED
DISABLED
Controls the optional Applicator Interface Card's GPIO function, where:
Sets the option to work with a specific device type, where:
Disables the option.
Enables parameters for related label applicator functions:
• Completion upon last SOP, de-asserts Data Ready (DRDY);
• FEED allowed at any time; and,
• DRDY upon PAUSE.
Enables parameters for alternate label applicator functions:
• Completion upon 1 msec. overlap of Data Ready (DRDY) and End of Print
(EOP);
• DRDY signal end inhibits FEED; and,
• De-asserts DRDY upon PAUSE or FAULT.
Enables the GPIO Port to work with a bar code verifier.
Selects the type of input signal required to initiate Start of Print (SOP), where:
Triggers printing with a low pulse.
Triggers printing with a high pulse.
Triggers printing with a low signal.
Triggers printing with a high signal.
Triggers printing with a signal edge transition.
Sets the type of output signal generated to indicate End of Print (EOP), where:
Outputs a low pulse upon completion.
Outputs a high pulse upon completion.
Outputs a logic low upon completion.
Outputs a logic high upon completion.
Sets the type of output signal generated to indicate Ribbon Low condition where:
Outputs a logic low upon condition.
Outputs a logic high upon condition..
Selects the type of input signal required to initiate label slew, where:
Triggers slew with a low signal.
Triggers slew with a low pulse.
Triggers slew with a high pulse.
Triggers slew with a low signal.
Triggers slew with a high signal.
Sets the output when a service required fault occurs (Applicator Interface Card
Type 2 equipped only), where:
Enables the output signal.
Disables the output signal.