Monitoring Functions - THOMSON LDK 20 S Operator's Manual

Studio camera
Table of Contents

Advertisement

Monitoring Functions

On-air indicators (red / yellow)
1
These LED indicators light red to indicate that the
camera is on-air or recording. They are also used as
ISO-indicators (yellow). This is a secondary indicator
which is controlled by a signal applied to the signalling
connector of the base station. It indicates that the
camera signal is being used for recording purposes
but is not on-air. On-air indication will override ISO.
Viewfinder signal selection switches
2
These four switches interactively select the signal to
be displayed in the viewfinder. The LED indicator in
the switch lights to show it is on. These switches are
used to choose between the local camera head Y
signal or the R, G, B, or inverted G signal for display
in the viewfinder. If all switches are off the Y signal is
selected.
Location of Controls and Functions
1
Camera Switch Panel
On Air
Power
Sys/Iso
light
Remote
Camera
View
Intercom
Audio
install
finder
Function
Function
Function
Function
A
B
C
D
Filter
Filter
Filter
Filter
1
2
3
4
Operator's Manual LDK 20(S) - Studio Camera
2
Auto
VTR
white
R
Ext.1
G
Ext.2
Select
B
Y/Ext.
Filter
Filter
-G
Call
5
6
External signal selection switches
3
These switches are used to select the external signal
displayed in the viewfinder. The LED indicator in the
switch lights to show it is on. The signal displayed for
each position is as follows:
Switch LED on
EXT 1
Base station external input 1.
EXT 2
Base station external input 2.
Y/EXT A mix of the external signal selected
and the camera head Y-signal.
In the stand-alone mode the viewfinder displays a
playback signal from the recorder for monitoring
purposes when the external 1 switch is on.
For PIP-functionality refer to the User's Guide of the
7-inch PIP Viewfinder (LDK 4016/05).
3
Note
4-5