If suspending the furnace from rafters or joist, use 3/8"
threaded rod and 2"x2"x1/8" angle iron as shown below.
The length of rod will depend on the application and the
clearances necessary.
PROVIDE 8" MINMUM CLEARANCE BETWEEN
3/8" DIAMETER
CENTER ROD AND FURNACE CABINET
THREADED ROD
TO ALLOW FOR CIRCULATOR BLOWER REMOVAL
(6 PLACES)
HOLD
DOWN
NUTS
SUPPORT
NUTS
2"X2"X3/8" DIAMETER
POSITION AS CLOSE AS POSSIBLE
ANGLE IRON
TO BLOWER DECK TO ALLOW FOR
(3 PLACES)
CIRCULATOR BLOWER REMVOAL
Suspended Furnace

Existing Furnace Removal

NOTE: When an existing furnace is removed from a
venting system serving other appliances, the venting
system may be too large to properly vent the remaining
attached appliances.
The following vent testing procedure is reproduced from the
American National Standard/National Standard of Canada
for Gas-Fired Central Furnaces ANSI Z21.47-1998,
CSA-2.3-M98 Section 1.23.1.
The following steps shall be followed with each appliance connected to
the venting system placed in operation, while any other appliances
connected to the venting system are not in operation:
a. Seal any unused openings in the venting system;
b. Inspect the venting system for proper size and horizontal pitch,
as required by the National Fuel Gas Code, ANSI Z223.1 or the
CSA B149 Installation Codes and these instructions. Determine
that there is no blockage or restriction, leakage, corrosion and
other deficiencies which could cause an unsafe condition;
c. In so far as practical, close all building doors and windows and
all doors between the space in which the appliance(s) connected
to the venting system are located and other spaces of the
building. Turn on clothes dryers and any appliance not con-
nected to the venting system. Turn on any exhaust fans, such as
range hoods and bathroom exhausts, so they shall operate at
maximum speed. Do not operate a summer exhaust fan. Close
fireplace dampers;
d. Follow the lighting instructions. Place the appliance being
inspected in operation. Adjust thermostat so appliance shall
operate continuously;
e. Test for draft hood equipped spillage at the draft hood relief
opening after 5 minutes of main burner operation. Use the flame
of a match or candle;
f. After it has been determined that each appliance connected to
the venting system properly vents when tested as outlined
General Information
Corrections must be in accordance with the latest edition
of the National Fuel Gas Code NFPA 54/ANSI Z223.1 and/
or CSA B149 Installation Codes.
ASSURE FURNACE IS LEVEL FROM
END TO END AND HAS A SLIGHT
If resizing is required on any portion of the venting system,
FORWARD TILT WITH THE FRONT
use the appropriate table in Appendix G in the latest edition
OF THE FURNACE 0"-3/4"BELOW
of the National Fuel Gas Code ANSI Z223.1 and/or
THE BACK OF THE FURNACE
CSA B149 Installation Codes.
TILT OUTWARD TO ALLOW
The two stage furnace requires a two stage thermostat for
FOR DOOR AND CIRCULATOR
proper operation. A two stage thermostat will have a "W2"
BLOWER REMOVAL
terminal in addition to a "W1" terminal. Refer to Electrical
Connections for proper hookup.
In an area having good air circulation, locate the thermo-
stat about five feet high on a vibration-free inside wall. Do
not install the thermostat where it may be influenced by any
of the following:
Consult the instructions packaged with the thermostat for
mounting instructions and further precautions.
9 9
above, return doors, windows, exhaust fans, fireplace dampers
and any other gas burning appliance to their previous conditions
of use;
g. If improper venting is observed during any of the above tests,
the common venting system must be corrected.

Thermostat Requirements

Thermostat Location

Drafts, or dead spots behind doors, in corners, or
under cabinets.
Hot or cold air from registers.
Radiant heat from the sun.
Light fixtures or other appliances.
Radiant heat from a fireplace.
Concealed hot or cold water pipes, or chimneys.
Unconditioned areas behind the thermostat, such
as an outside wall.
DRAFTS OR DEAD SPOTS
-BEHIND DOORS
-IN CORNERS
-UNDER CABINETS
Thermostat Influences