To prevent death, personal injury, or property damage due to fire or explosion from a propane gas leak, install a
gas detecting warning device. A gas detecting warning device is the only reliable way to detect a propane gas
leak. Do not rely on smell as rust can reduce the level of odorant in propane gas.
Remember:
Propane gas is heavier than air and leaking gas can settle in any low area or confined space.
A propane gas odor can fade, making the gas undetectable.
A warning device is a required item, if the propane gas unit is installed in either a basement, an excavated area or
a confined space.
If the presence of gas is suspected:
Do not try to light any appliance.
Do not touch any electrical switch or use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
IN CANADA "THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF
THE PROVINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF
THE CAN/CSA B149.1 AND B149.2 INSTALLATION CODE."
IMPORTANT NOTE: Propane gas conversion kits must
be installed to convert units to propane gas. See
Specification Sheet for kit part number for this model.
All propane gas equipment must conform to the safety
standards of the National Board of Fire Underwriters (See
NBFU Manual 58).
For satisfactory operation, propane gas supply pressure
must be 11 inch W.C. at the unit manifold with all gas
appliances in operation. Maintaining proper gas pressure
depends on three main factors:
1. Vaporization rate, which depends on (a) temperature
of the liquid, and (b) wetted surface area of the con-
tainer or containers.
2. Proper pressure regulation. (Two-stage regulation is
recommended for both cost and efficiency).
3. Pressure drop in lines between regulators, and be-
tween second stage regulator and the appliance.
Pipe size required will depend on length of pipe run
and total load of all appliances.
Complete information regarding tank sizing for vaporiza-
tion, recommended regulator settings, and pipe sizing is
available from most regulator manufacturers and propane
gas suppliers.

Propane Gas Tanks and Piping

PERSONAL INJURY HAZARD
WARNING
Since propane gas will quickly dissolve white lead and
most standard commercial compounds, special pipe dope
must be used. Shellac-based compounds resistant to the
actions of liquefied petroleum gases such as Gasolac
Stalactic
®
, Clyde's
Refer to the following illustration for typical propane gas
installations.
First Stage
Regulator
200 PSIG
Maximum
Propane Gas Installation (Typ.)
23
23
®
or John Crane
®
are satisfactory.
5 to 15 PSIG
(20 PSIG Max.)
Second Stage
Regulator
,
®
Continuous
11" W.C.