Diagnostics
Field
Description
r dc
r
S
00
MAC Abort Cntr
This counter increments every time the MAC layer reaches the cell abort count
limit. It is reset by the successful upstream transmission of a cell: for example,
when the DCX3501-M receives an ACK. If the counter reaches the MAC abort
count limit, the DCX3501-M assumes the MAC layer is unavailable due to noise,
congestion, or some other problem. The DCX3501-M stops transmitting data
upstream, reports an error to the calling function, and attempts to re-enter the
network using the initialization process. 0000 is displayed as the default or the MAC
Abort CNTR is unconfigured or unknown.
Socket Port State
The socket mode and activity:
• UNKNOWN — The socket state is invalid or unknown.
High-Definition DVR DCX3501-M • Installation Manual
365-095-16528-x.2
RUN_WAIT_DC_OR_C
RUNNING
RUN_STOPPED
INVALID
UNUSED — The socket is not being used.
OPENED — The socket is open.
READY — The socket is ready to send or receive.
RECEIVING — The socket is receiving data from the application server.
SENDING — The socket is sending data to the application server.
The DCX3501-M is in the interactive
state and waiting for the default
configuration or the contention
channel list messages.
Interactive state is running, sending
idle messages, and waiting for any
prepare for poll or MAC messages.
The interactive run state has stopped
and DCX3501-M is waiting for status
or a transmission control message.
The interactive state is unknown or
invalid.