3. Wiring DC Power Inputs

The 6-contact terminal block connector on the rear panel of the MGSW-28240F is
used for two DC redundant power inputs. Please follow the steps below to insert
the power wire.
1. Insert positive / negative DC power wires into the contacts 1 and 2 for DC
POWER 1, or 5 and 6 for DC POWER 2.
ON
100~240V AC
OFF
2. Tighten the wire-clamp screws for preventing the wires from loosening.
The wire gauge for the terminal block should be in the range of 12
~ 24 AWG.