Table 86. Post Error Beep Codes - Intel S2600IP Technical Product Specification

Server and workstation board
Hide thumbs Also See for S2600IP:
Table of Contents

Advertisement

Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Appendix E: POST Error Messages and Han
Error Code
85ED
DIMM_P1 encountered a Serial Presence Detection (SPD) failure
85EE
DIMM_P2 encountered a Serial Presence Detection (SPD) failure
85EF
DIMM_P3 encountered a Serial Presence Detection (SPD) failure
8604
POST Reclaim of non-critical NVRAM variables
8605
BIOS Settings are corrupted
8606
NVRAM variable space was corrupted and has been reinitialized
92A3
Serial port component was not detected
92A9
Serial port component encountered a resource conflict error
A000
TPM device not detected.
A001
TPM device missing or not responding.
A002
TPM device failure.
A003
TPM device failed self test.
A100
BIOS ACM Error
A421
PCI component encountered a SERR error
A5A0
PCI Express* component encountered a PERR error
A5A1
PCI Express* component encountered an SERR error
DXE Boot Services driver: Not enough memory available to shadow a
A6A0
Legacy Option ROM.
POST Error Beep Codes
The following table lists the POST error beep codes. Prior to system video initialization, the
BIOS uses these beep codes to inform users on error conditions. The beep code is followed by
a user-visible code on the POST Progress LEDs
Beeps
Error Message
1
USB device action
®
1 long
Intel
TXT security
violation
3
Memory error
2
BIOS Recovery
started
4
BIOS Recovery
failure
The Integrated BMC may generate beep codes upon detection of failure conditions. Beep codes
are sounded each time the problem is discovered, such as on each power-up attempt, but are
not sounded continuously. Codes that are common across all Intel server boards and systems
that use same generation chipset are listed in the following table. Each digit in the code is
represented by a sequence of beeps whose count is equal to the digit.
Revision 1.1
Error Message

Table 86. POST Error Beep Codes

POST Progress Code
NA
Short beep sounded whenever a USB device is discovered
in POST, or inserted or removed during runtime
0xAE, 0xAF
System halted because Intel
Technology detected a potential violation of system
security.
See Tables 28 and 29
System halted because a fatal error related to the memory
was detected.
NA
Recovery boot has been initiated
NA
BIOS recovery has failed. This typically happens so quickly
after recovery us initiated that it sounds like a 2-4 beep
code.
Intel order number G34153-003
Response
Major
Major
Major
Minor
Major
Major
Major
Major
Minor
Minor
Minor
Minor
Major
Fatal
Minor
Fatal
Minor
Description
®
Trusted Execution
167

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

W2600crS2600ip

Table of Contents