Jenn-Air JGC1530B Series Instructions Manual page 9

Lp gas and high altitude conversion
Hide thumbs Also See for JGC1530B Series:
Table of Contents

Advertisement

Available languages

Available languages

7. Check burner flame(s) for proper size and shape. The
cooktop "low" burner flame should be a steady blue flame
approximately ¹⁄₄" (6.4 mm) high.
A
B
Standard burner
A. Low flame
B. High flame
A
Dual flame burner
A. Simmer flame
B. High flame
8. Completely fill out the conversion label and attach label to
9. Save the orifices removed from the cooktop along with these
Read "Sealed Surface Burners" section in the Use and Care
Guide supplied with your cooktop.
B
bottom of the cooktop next to the rating tag. Do not cover the
rating tag with the conversion label.
instructions for future reference.