GAS LINE HOOK-UP
WARNING: Gas line hookup
should be done by your gas
supplier or a qualified service
person.
WARNING: Before you pro-
ceed, make sure your gas supply
is OFF.
A manual shutoff valve has been included in
the appliance's gas supply system. You may
consider installing an extra gas shutoff valve
outside appliance's enclosure (check with
local codes) where it can be accessed more
conveniently with a key through a wall as
shown in Figure 16.
In conformance with local codes, route a
1/2" NPT gas line to appliance through hole
in left side of firebox or sub-floor as shown
in Figure 17.
CAUTION: Do not kink flex-
ible gas line.
126737-01B
INSTALLATION
Battery Cover
12 Volt Battery
Back of
Handset
Pull to Remove
Insulation Tab
www.SuperiorFireplaces.US.com
Continued
INNOVATIVE HEARTH PRODUCTS recom-
mends that a black iron gas line be routed
from the gas source, through a sediment trap
(shown in Figure 18) and into appliance. Once
connected through appliance, a flexible gas
line may be used for ease of installation to
gas control valve (see Figure 19, page 14).
Before connecting black iron gas line to inside
of appliance a sediment trap must be included
outside appliance between gas line and gas
shutoff valve. It must extend down 3" beyond
center of pipe. Prepare incoming black iron
gas line with teflon tape or pipe joint com-
pound (Check with local building codes).
Key
Typical Exterior Wall Gas
Shutoff Installation
Figure 16 - Manual Shutoff Valve
1/2" NPT Incoming
Black Iron Gas Line
A
7"
BRT 4036TEN,
4336TEN, 4536TEN,
4036TEP, 4336TEP,
A
8
/
5
8
Figure 17 - Routing Incoming Gas Line
Sediment
Trap (Not
Supplied)
Figure 18 - Sediment Trap
Installation
7"
Alternate Gas Supply
Through Sub-Floor
BRT 4042TEN,
4342TEN, 4542TEN,
4042TEP, 4342TEP,
4536TEP
" (21.9 cm)
10
3" Min.
(7.6 cm)
Shutoff
Valve
Extension
Flexible Gas Line
(1 Provided) Can
Be Extended Out
Either Side
B
4542TEP
/
" (26.7 cm)