Pager Options - Honeywell ADEMCO VISTA-20P Programming Manual

Ademco vista series security systems
Hide thumbs Also See for ADEMCO VISTA-20P:
Table of Contents

Advertisement

∗ ∗ ∗ ∗ 88
Program Mode Lockout Options
0 = standard *98 installer code lockout (reentry only by [∗] + [#] within
50 seconds after power up)
1 = lockout [∗] + [#] reentry after *98 exit (reenter via installer code or
downloader only)
2 = not used
3 = lockout local programming after *98 exit (reenter by downloader only)
∗ ∗ ∗ ∗ 89
Event Log Full Report Code
See box above field *59 for report code entries.
∗ ∗ ∗ ∗ 90
Event Log Enables
NOTE : System messages are logged when any non-zero entry is made.
0 = None; 1 = Alarm/Alarm Restore
2 = Trouble/Trouble Restore;
4 = Bypass/Bypass Restore;
8 = Open/Close. Example: To select "Alarm/Alarm Restore", and
"Open/Close", enter 9 (1 + 8); To select all, enter #15.
∗ ∗ ∗ ∗ 91
Option Selection
Options: 0 = None
4 = AAV UL: must use ADEMCO UVCM module
8 = Exit Delay Restart/Reset UL: must be disabled
#+12 = AAV and Exit Delay Restart/Reset
SIA Guidelines: Exit Delay should be enabled.
V20PSIA/V15PSIA:
Options: Same as listed above.
Call Waiting Disable:
0 = call waiting not used
1 = call waiting disable digits (*70) entered in field *40; (when
selected, the system dials the entry in field *40 only on
alternate dial attempts; this allows proper dialing in the event
call waiting service is later canceled by the user).
∗ ∗ ∗ ∗ 92
Phone Line Monitor Enable
UL: see Inst. Instructions for requirements
NOTE: Output Device must either be programmed to be STOPPED in
field ✱80 or STOPPED by Code + # + 8 + output number.
Entry 1:: 0 = disabled, 1-15 = 1 min - 15 min
(#+10 = 10 min; #+11 = 11 min; #+12 = 12 min; #+13 = 13 min; #+14
= 14 min; #+15 = 15 min)
Entry 2:
0 = Keypad display when line is faulted
1 = Keypad display plus keypad trouble sound
2 = Same as "1", plus programmed output device STARTS. If either
partition is armed, external sounder activates also.
∗ ∗ ∗ ∗ 93
Reports In Armed Period
Per Zone
(Swinger Suppression)
Restrict Report Pairs:
0 = Unlimited Reports
1 = 1 report pair
2 = 2 report pairs
SIA Guidelines: Must be set for option 1 or 2.
V20PSIA/V15PSIA:
Restrict Report Pairs: 1 = 1 report pair; 2 = 2 report pairs
Unlimited Reports Enable:
0 = restrict reports to the setting in entry 1
1 = unlimited reports for zones listed in zone list 7; (use zone list 7
to enter those zones that require unlimited reporting; these
zones ignore the setting in entry 1)
DOWNLOAD INFORMATION ( ✱ 94, ✱ 95)
∗ ∗ ∗ ∗ 94
Download Phone No.
|
|
|
|
|
|
|
|
|
Enter up to 20 digits, 0–9; #+11 for ' ✱ '; #+12 for '#'; #+13 for a 2-
second pause. Do not fill unused spaces. If fewer than 20 digits, exit
field by pressing ✱ . To clear entries from field, press ✱ 94 ✱ .
UL: downloading may be performed only if a technician is at the site.
∗ ∗ ∗ ∗ 95
Ring Count For Downloading
NOTE: Do not enter "0" if using 4285/4286 Phone Module.
0 = Disable Station Initiated Download;
1–14 = number of rings (1–9, # +10 =10, # +11 =11,
# +12 =12, # +13 =13, # +14 =14);
15 = answering machine defeat (# +15 =15).
[0]
[00]
|
[3]
[8, 0]
Options
V20PSIA/V15PSI
Call Wait Disable
[0,0]
1
[1,0]
Restrict
V20PSIA/V15PSIA
Report Pairs
Unlimited
Reports Enable
|
|
|
|
|
|
|
|
|
|
[15]
∗ ∗ ∗ ∗ 96
, ∗ ∗ ∗ ∗ 97
Initialize/Reset Defaults
This is a command, not a data field. See page 2.
∗ ∗ ∗ ∗ 98
Exit Commands
, *99
This is a command, not a data field. See page 2.
PAGER OPTIONS (✱160- ✱172)
∗ ∗ ∗ ∗ 160
Pager 1 Phone No.
|
|
|
|
|
|
Enter up to 20 digits. 0–9; #+11 = ' ✱ '; #+12 = '#'; #+13 = 2-sec pause
∗ ∗ ∗ ∗ 161
Pager 1 Characters
|
|
|
|
|
Enter the optional prefix characters, up to 16 digits.
0–9; #+11 = ' ✱ '; #+12 = '#'; #+13 = 2-second pause.
∗ ∗ ∗ ∗ 162
Pager 1 Report Options
A
Part. 1 Part. 2 common
For each partition, select from the following options:
0 =
no reports sent
1 =
Opens/closes all users
4 =
All alarms and troubles
5 =
All alarms / troubles, and opens/closes for all users
12 = Alarms / troubles for zones entered in zone list 9
13 = Alarms / troubles for zones entered in zone list 9, and
opens/closes for all users
∗ ∗ ∗ ∗ 163
Pager 2 Phone No.
|
|
|
|
|
|
Enter up to 20 digits. 0–9; #+11 = 'Q'; #+12 = '#'; #+13 = 2-sec pause
∗ ∗ ∗ ∗ 164
Pager 2 Characters
|
|
|
|
|
2
Enter the optional prefix characters, up to 16 digits.
0–9; #+11 = ' ✱ '; #+12 = '#'; #+13 = 2-second pause.
∗ ∗ ∗ ∗ 165
Pager 2 Report Options
Part. 1 Part. 2 common
See field *162 for reporting options. Select for each partition (use zone
list 10 if using options 12 or 13).
∗ ∗ ∗ ∗ 166
Pager 3 Phone No.
|
|
|
|
|
|
Enter up to 20 digits. 0–9; #+11 = ' ✱ '; #+12 = '#'; #+13 = 2-sec pause
∗ ∗ ∗ ∗ 167
Pager 3 Characters
|
|
|
|
Enter the optional prefix characters, up to 16 digits.
0–9; #+11 = ' ✱ '; #+12 = '#'; #+13 = 2-second pause.
∗ ∗ ∗ ∗ 168
Pager 3 Report Options
Part. 1 Part. 2 common
See field *162 for reporting options. Select for each partition (use zone
list 11 if using options 12 or 13).
∗ ∗ ∗ ∗ 169
Pager 4 Phone No.
|
|
|
|
|
|
Enter up to 20 digits. 0–9; #+11 = ' ✱ '; #+12 = '#'; #+13 = 2-sec pause
∗ ∗ ∗ ∗ 170
Pager 4 Characters
|
|
|
|
Enter the optional prefix characters, up to 16 digits.
0–9; #+11 = ' ✱ '; #+12 = '#'; #+13 = 2-second pause.
∗ ∗ ∗ ∗ 171
Pager 4 Report Options
Part. 1 Part. 2 common
See field *162 for reporting options. Select for each partition (use zone
list 12 if using options 12 or 13).
∗ ∗ ∗ ∗ 172
Pager Delay Option For Alarms
0 = none; 1 = 1 minute; 2 = 2 minutes; 3 = 3 minutes
This delay is for ALL pagers in the system.
– 5 –
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
[0,0,0]
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
[0,0,0]
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0,0,0]
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
[0,0,0]
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
[3]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents