Drum Temperatures
The following tests should be run with an unrestricted
exhaust. The location of the thermal couple is to be
the square in the lint grill which is 12 squares left from
the right edge of the lint blade and (2) squares forward.
The tip should extend 1.25" into the air grill. Set the
dryer timer as needed for each test. The recordable
temperature is to be the maximum temperature
following the heater off of the 3rd cycle.
No load is to be used for following heat settings:
Heat Setting
Thermistor Status
Max*
Satisfied/Heater Off
Medium*
Satisfied/Heater Off
Low*
Satisfied/Heater Off
* Each opening temperature should be equal to or
higher than the opening temperature for the next lower
temperature
setting.
Troubleshooting Flowcharts
The following pages are flowcharts for diagnosing and troubleshooting gas and electric dryers.
Electric dryers; blower motor runs but dryer does not heat............................... 3-27
Gas dryers; blower motor runs but dryer does not heat.................................... 3-28
Section 3 Electronic Control Testing
Temperature °F
120 to 180
105 to 145
95 to 130
3-21