LYNX Touch Installation and Setup Guide
Zone Programming Default Tables
Zone Assignment/Alarm Report Codes for Table 2
Zone
Loop
Device Type
Number
Number
1
---
New
2
2
Door
3
2
Door
4
2
Door
5
1
Motion Sensor
6
1
Smoke Detector
49
3
4 Button Key
50
2
4 Button Key
51
4
4 Button Key
52
1
4 Button Key
53
3
4 Button Key
54
2
4 Button Key
55
4
4 Button Key
56
1
4 Button Key
92
---
---
95
---
Fire
96
---
Medical
97
---
---
99
---
Police
NOTE: Zone 1 is a hardwire zone; Zone 2 to 48 are RF zones; Zone 92 is Duress; Zone 99 is keypad panic
Zone Assignment/Alarm Report Codes for Tables 3 and 4
Zone
Loop
Device Type
Number
Number
1
---
New
2
2
Door
3
2
Door
4
2
Window
5
2
Window
6
2
Window
7
2
Window
8
1
Motion Sensor
9
1
Smoke Detector
49
3
4 Button Key
50
2
4 Button Key
51
4
4 Button Key
52
1
4 Button Key
53
3
4 Button Key
54
2
4 Button Key
55
4
4 Button Key
56
1
4 Button Key
92
---
---
95
---
Fire
96
---
Medical
97
---
99
---
Police
NOTE: Zone 1 is a hardwire zone; Zone 2 to 48 are RF zones; Zone 92 is Duress; Zones 95, 96 and 99 are keypad panics
Response Type
n/a
Entry Exit 1
Entry Exit 1
Entry Exit 1
Interior w/Delay
Fire No verification
Arm Away
Disarm
Arm Stay
No Response
Arm Away
Disarm
Arm Stay
No Response
---
Fire No Verification
24-Hour Auxiliary
---
24-Hour Audible
Response Type
n/a
Entry Exit 1
Entry Exit 1
Perimeter
Perimeter
Perimeter
Perimeter
Interior w/Delay
Fire No Verification
Arm Away
Disarm
No Response
No Response
Arm Away
Disarm
No Response
No Response
---
Fire No Verification
n/a
---
24-Hour Silent
WWW.DIYALARMFORUM.COM
Supervision/
Report
Chime
Input Type
yes
no
EOLR
yes
yes
RF Supervised
yes
yes
RF Supervised
yes
yes
RF Supervised
yes
no
RF Supervised
yes
no
RF Supervised
yes
no
Button
yes
no
Button
yes
no
Button
no
no
Button
yes
no
Button
yes
no
Button
yes
no
Button
no
no
Button
yes
no
Duress Trigger
yes
no
Panic Trigger
yes
no
Panic Trigger
yes
no
Cover Tamper
yes
no
Panic Trigger
Supervision/
Report
Chime
Input Type
yes
no
EOLR
yes
yes
RF Supervised
yes
yes
RF Supervised
yes
no
RF Supervised
yes
no
RF Supervised
yes
no
RF Supervised
yes
no
RF Supervised
yes
no
RF Supervised
yes
no
RF Supervised
yes
no
Button
yes
no
Button
yes
no
Button
no
no
Button
yes
no
Button
yes
no
Button
yes
no
Button
no
no
Button
yes
no
Duress Trigger
yes
no
Panic Trigger
yes
no
Panic Trigger
yes
no
Cover Tamper
yes
no
Panic Trigger
- 62 -
Zone Descriptor
n/a
Front Door
Back Door
Garage Door
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
Zone Descriptor
n/a
Front Door
Back Door
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a