Table 3. List of POST error codes (continued)
v Follow the suggested actions in the order in which they are listed in the Action
column until the problem is solved.
v See the parts listing in the Problem Determination and Service Guide to determine
which components are customer replaceable units (CRU) and which components
are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must
be performed only by a trained service technician.
Error code
Description
101, 102
System and microprocessor error.
151
Real-time clock error.
161
Real-time clock battery error.
Action
1. (Trained service technician
only) Replace the system
board.
1. Reseat the battery.
2. Replace the following
components one at a time, in
the order shown, restarting the
server each time:
a. System-board battery
b. (Trained service technician
only) System board
1. Run the Configuration/Setup
Utility program, select Load
Default Settings, and save the
settings.
2. Reseat the battery.
3. Replace the following
components one at a time, in
the order shown, restarting the
server each time:
a. System-board battery
b. (Trained service technician
only) System board
Chapter 6. Solving problems
47