Download Print this page

Physical And Electrical Data - York YMB018 THRU 060 Technical Manual

Affinity split-system heat pumps 13 seer – r-22 models: ymb018 thru 060 (1.5 thru 5 nominal tons)

Advertisement

246809-YTG-E-0507

Physical and Electrical Data

MODEL
Unit Supply Voltage
1
Normal Voltage Range
Minimum Circuit Ampacity
Max. Overcurrent Device Amps
Min. Overcurrent Device Amps
4
Compressor Type
Rated Load
Compressor Amps
Locked Rotor
Crankcase Heater
Fan Motor Amps
Rated Load
Fan Diameter Inches
Rated HP
Fan Motor
Nominal RPM
Nominal CFM
Face Area Sq. Ft.
Coil
Rows Deep
Fin / Inches
Liquid Line Set OD (Field Installed)
Vapor Line Set OD (Field Installed)
5
Unit Charge (Lbs. - Oz.)
Charge Per Foot, Oz.
Operating Weight Lbs.
1 Rated in accordance with ARI Standard 110, utilization range "A".
2 Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3 Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4 All scrolls listed with superscript "D" are Danfoss scrolls. All scrolls listed with superscripts "C" are Copeland scrolls.
5 The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than
15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.
A
VAPOR
3-1/8
6-1/2
LIQUID
2-3/8
2
YMB01811
YMB02411
11.7
14.5
2
20
25
3
15
15
C
Scroll
Scroll
10.0
12.1
41
54
No
No
0.5
0.5
22
22
1/15
1/15
850
850
1,900
1,800
14.86
17.15
1
1
22
22
3/8
3/8
3/4
3/4
6 - 6
7 - 9
0.68
0.68
175
190
B
C
YMB03011
YMB03611
208/230 – 1 – 60
187 to 252
16.7
20.0
25
30
20
20
C
C
Recip
Scroll
13.6
13.4
67
78
No
Yes
1.5
1.5
22
24
1/4
1/4
850
850
3,300
3,600
20.58
23.58
1
1
22
22
3/8
3/8
7/8
7/8
9 - 1
9 - 9
0.70
0.70
195
258
All dimensions are in inches. They are subject to change
without notice. Certified dimensions will be provided upon
request.
Unit
Model
A
018
29-1/2
024
33-1/2
030
39-1/2
036
39-1/2
042
39-1/2
048
39-1/2
060
39-1/2
*
Expander fitting required for 1-1/8" lineset.
YMB04211
YMB04811
27.8
33.9
45
50
30
35
D
D
Scroll
Scroll
21.0
23.0
115
115
No
No
1.5
1.5
24
24
1/4
1/4
850
850
3,600
3,400
23.58
23.58
1
2
22
22
3/8
3/8
7/8
7/8
10 - 9
13 - 1
0.70
0.70
258
278
Refrigerant
Dimensions
Connection
(Inches)
Service Valve Size
B
C
Liquid
37
31
37
31
37
31
42
34
3/8"
42
34
42
34
42
34
Unitary Products Group
YMB06011
40.2
60
45
D
Scroll
25.0
150
No
1.5
24
1/4
850
3,400
23.58
2
22
3/8
1-1/8
14 - 11
0.76
278
Vapor
3/4"
7/8"
1-1/8"

Hide quick links:

Advertisement

loading