HEATING PERFORMANCE DATA
OUTDOOR UNIT MODEL NO.
INDOOR COIL MODEL NO.
AIR TEMP.
AIR TEMP.
ENTERING
ENTERING
OUTDOOR
INDOOR
UNIT
COIL
60
47
40
30
17
10
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
Air Handler
Coil
MA20D
FC/MC60D
MA20D
MC61D
MV20D
FC/MC60D
MV20D
MC61D
AV/SV60
–
F*FV060
–
AHP/SHP60
–
–
HC60
–
HD60
–
MC61
Unitary Products Group
YMB06011
FC/MC/PC60
1600
MBTUH
KW
60
75.6
4.6
70
72.9
5.1
80
70.2
5.6
60
63.8
4.3
70
61.4
4.8
80
59.0
5.3
60
53.1
4.0
70
48.9
4.4
80
44.7
4.7
60
47.5
4.1
70
46.6
4.5
80
45.7
4.9
60
38.3
3.8
70
36.8
4.0
80
35.3
4.3
60
33.1
3.4
70
33.2
3.9
80
33.4
4.4
MBH
KW
1.00
1.00
1.00
1.00
1.00
1.02
1.00
1.02
1.00
1.02
1.00
1.02
1.00
1.01
1.00
1.00
1.00
1.00
1.00
1.00
ID CFM
1800
C.O.P.
MBTUH
KW
4.8
76.1
4.4
4.2
73.4
4.9
3.7
70.6
5.3
4.4
64.2
4.1
3.8
61.8
4.6
3.3
59.3
5.0
3.9
53.2
4.2
3.3
49.3
4.6
2.7
45.4
5.0
3.4
48.8
3.9
3.0
47.3
4.4
2.7
45.8
4.8
2.9
40.1
3.6
2.7
38.4
4.0
2.4
36.7
4.3
2.9
34.5
3.5
2.5
34.0
3.9
2.2
33.4
4.3
COP
Variable Speed
Furnace
1.00
P(C,V)9*D20
1.00
PV8*C20
0.98
P(C,V)9*C20
0.98
PV8*C20
P(C,V)9*D20
0.98
PV8*C20
0.98
P(C,V)9*C20
0.99
P(C,V)9*D20
1.00
PV8*C20
1.00
P(C,V)9*C20
P(C,V)9*D20
1.00
246809-YTG-E-0507
2000
C.O.P.
MBTUH
KW
5.1
76.6
4.2
4.4
73.8
4.6
3.9
71.0
5.1
4.6
64.7
3.9
4.0
62.2
4.4
3.4
59.6
4.8
3.7
53.3
4.3
3.1
49.6
4.8
2.7
46.0
5.2
3.6
50.2
3.7
3.2
48.1
4.2
2.8
45.9
4.6
3.2
41.9
3.5
2.8
40.0
3.9
2.5
38.1
4.4
2.9
36.0
3.6
2.5
34.7
3.9
2.2
33.4
4.3
T.C.
Coil
FC/MC/PC60D
1.00
FC/PC60C
1.00
FC/PC60C
1.00
HC60
1.00
HC60
1.00
HD60
1.00
HD60
1.00
HD60
1.00
MC61D
1.00
MC61D
1.00
MC61D
1.00
C.O.P.
5.3
4.7
4.1
4.8
4.2
3.6
3.6
3.0
2.6
3.9
3.4
2.9
3.5
3.0
2.6
2.9
2.6
2.3
S.C.
KW
1.02
0.98
1.01
0.99
1.01
0.99
1.01
0.99
1.02
0.98
1.01
0.99
1.01
0.99
1.02
0.98
1.01
0.99
1.01
0.99
1.02
0.98
27