1. Rated in accordance with AHRI Standard 110-2012, utilization range "A".
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4. For applications with non-standard vapor line sizes, see the "Applications & Accessories" section of this Technical Guide.
5. The Unit Charge is correct for the outdoor unit, smallest matched indoor unit, and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract
the amount of refrigerant, using the difference in actual lineset length (not the equivalent length) multiplied by the per foot value.
Johnson Controls Ducted Systems
THE30
THE36
B31S
B32S
208-230V, 3, 60Hz
12.5
15.8
2
20
25
3
15
20
Scroll
Scroll
9.9
10.4
58.0
73.0
No
No
Yes
Yes
24
26
PSC
ECM
1/4
1/3
1.30
2.8
850
834
2995
3715
23.82
26.40
1
1
22
22
3/8
3/8
4
3/4
3/4
7 - 15
9 - 1
0.62
0.62
181
235
THE42
THE48
THE60
B33S
B31S
B31S
187 to 252
19.7
18.5
21.3
30
30
35
20
20
25
Scroll
Scroll
Scroll
13.5
15.3
17.8
88.0
83.1
110.0
No
No
No
Yes
Yes
Yes
26
26
26
ECM
PSC
PSC
1/3
1/4
1/4
2.8
1.30
1.30
834
850
850
4000
4100
4100
26.40
26.40
28.80
1
2
2
22
18
18
3/8
3/8
3/8
‡
7/8
7/8
1-1/8
10 - 5
15 - 4
14 - 10
0.67
0.67
0.75
235
240
261
DIMENSIONS
Unit
Model
THE30B(3,4)1S 39-1/2
THE36B(3,4)2S 39-1/2
THE42B(3,4)3S 39-1/2
THE48B(3,4)1S 39-1/2
THE60B(3,4)1S 42-3/4
‡ Adapter fitting must be field installed for the required 1-1/8" line set.
All dimensions are in inches and are subject to change without notice.
Overall height is from bottom of base pan to top of fan guard.