TABLE 2: 15Z24AC Subcooling Charging Chart
Outdoor
Ambient
57
DB (°F)
Liquid Pressure (psig) at Base Valve
65
234 (10)
70
255 (11)
75
277 (12)
80
299 (12)
85
323 (12)
90
347 (12)
95
372 (13)
100
398 (13)
105
425 (13)
110
453 (13)
115
482 (13)
120
511 (13)
125
542 (13)
TABLE 3: 15Z36AC Subcooling Charging Chart
Outdoor
Ambient
57
DB (°F)
Liquid Pressure (psig) at Base Valve
65
229 (9)
70
250 (10)
75
272 (11)
80
295 (11)
85
318 (11)
90
343 (11)
95
368 (11)
100
394 (11)
105
421 (11)
110
449 (11)
115
478 (11)
120
507 (10)
125
537 (10)
Unitary Products Group
Indoor Wet Bulb (°F)
62
67
72
235 (11)
238 (11)
241 (10)
256 (12)
259 (12)
263 (11)
278 (12)
282 (13)
285 (12)
300 (12)
304 (13)
309 (13)
324 (12)
328 (13)
333 (13)
348 (13)
353 (13)
358 (13)
373 (13)
378 (13)
383 (13)
399 (13)
404 (13)
410 (14)
426 (13)
431 (14)
437 (14)
454 (13)
459 (14)
465 (14)
483 (14)
488 (14)
493 (14)
512 (14)
517 (14)
523 (14)
543 (13)
548 (13)
553 (13)
Indoor Wet Bulb (°F)
62
67
72
231 (10)
234 (11)
240 (12)
252 (11)
255 (12)
260 (13)
274 (11)
277 (12)
282 (13)
297 (11)
300 (12)
305 (13)
320 (11)
323 (12)
328 (13)
345 (11)
348 (11)
352 (12)
370 (11)
373 (11)
377 (12)
396 (11)
399 (11)
403 (12)
423 (11)
426 (11)
430 (12)
451 (11)
454 (11)
457 (12)
480 (11)
483 (11)
486 (12)
509 (10)
512 (11)
515 (11)
539 (10)
542 (10)
545 (10)
66901 / 035-20393-001 Rev. C (1204)
TABLE 4: 15Z48AC Subcooling Charging Chart
Indoor Wet Bulb (°F)
Outdoor
Ambient
57
DB (°F)
Liquid Pressure (psig) at Base Valve
65
235 (9)
70
255 (10)
257 (10)
75
277 (11)
279 (11)
80
299 (11)
301 (11)
85
322 (11)
323 (11)
90
346 (10)
347 (10)
95
370 (10)
371 (10)
100
395 (10)
396 (10)
105
421 (10)
421 (10)
110
448 (10)
448 (10)
115
475 (10)
475 (10)
120
504 (9)
504 (9)
125
532 (9)
532 (9)
TABLE 5: 15Z60AC Subcooling Charging Chart
Indoor Wet Bulb (°F)
Outdoor
Ambient
57
DB (°F)
Liquid Pressure (psig) at Base Valve
65
244 (10)
247 (11)
70
266 (11)
269 (12)
75
288 (12)
291 (12)
80
311 (12)
314 (12)
85
336 (12)
339 (12)
90
361 (12)
364 (12)
95
386 (12)
389 (12)
100
413 (12)
415 (12)
105
440 (12)
442 (12)
110
468 (12)
470 (12)
115
497 (12)
499 (12)
120
526 (11)
528 (11)
125
556 (10)
558 (10)
62
67
72
237 (9)
240 (10)
245 (10)
260 (10)
266 (11)
282 (11)
288 (12)
304 (11)
310 (12)
327 (11)
333 (12)
351 (11)
357 (11)
375 (10)
381 (11)
400 (10)
406 (11)
426 (10)
432 (11)
452 (10)
459 (11)
479 (10)
486 (10)
507 (9)
514 (10)
535 (9)
542 (9)
62
67
72
252 (11)
255 (12)
274 (12)
278 (13)
296 (12)
301 (13)
319 (12)
324 (13)
344 (12)
349 (13)
369 (12)
375 (13)
394 (12)
400 (12)
420 (12)
427 (12)
447 (12)
454 (12)
474 (12)
481 (12)
503 (12)
510 (12)
532 (11)
539 (11)
562 (11)
569 (11)