SECTION VIII: SYSTEM START-UP
INDICATIONS OF PROPER OPERATION
Cooling
1.
The outdoor fan should be running, with warm air being dis-
charged from the top of the unit.
2.
The indoor blower (furnace or air handler) will be operating, dis-
charging cool air from the ducts. Coils or other parts in the air cir-
cuit should be cleaned as often as necessary to keep the unit
clean. Use a brush, vacuum cleaner attachment, or other suitable
means.
3.
The vapor line at the outdoor unit will feel cool to the touch.
4.
The liquid line at the outdoor unit will feel warm to the touch.
Instructing the Owner
Assist owner with processing warranty cards and/or online registration.
Review Owners Manual, provide a copy to the owner, and provide guid-
ance on proper operation and maintenance. Instruct the owner or the
operator how to start, stop, and adjust temperature setting.
The installer should also instruct the owner on proper operation and
maintenance of all other system components.
TABLE 1: R-410A Saturation Properties
PRESSURE
TEMP. °F
PSIG
45
129.70
46
132.20
47
134.60
48
137.10
49
139.60
50
142.20
51
144.80
52
147.40
53
150.10
54
152.80
55
155.50
56
158.20
57
161.00
58
163.90
59
166.70
8
PRESSURE
TEMP. °F
TEMP. °F
PSIG
60
169.60
61
172.60
62
175.50
63
178.50
64
181.60
65
184.60
66
187.70
67
190.90
68
194.10
69
197.30
70
200.60
71
203.90
72
207.20
73
210.60
74
214.00
Maintenance
1.
Dirt should not be allowed to accumulate on the outdoor coils or
other parts in the air circuit. Clean as often as necessary to keep
the unit clean. Use a brush, vacuum cleaner attachment, or other
suitable means.
2.
The outdoor fan motor is permanently lubricated and does not
require periodic oiling.
3.
If the coil needs to be cleaned, it should be washed with Calgon
Coilclean (mix one part Coilclean to seven parts water). Allow
solution to remain on coil for 30 minutes before rinsing with clean
water. Solution should not be permitted to come in contact with
painted surfaces.
4.
Refer to the furnace or air handler instructions for filter and blower
motor maintenance.
5.
The indoor coil and drain pan should be inspected and cleaned
regularly to prevent odors and assure proper drainage.
IT IS UNLAWFUL TO KNOWINGLY VENT, RELEASE OR DIS-
CHARGE REFRIGERANT INTO THE OPEN AIR DURING
REPAIR, SERVICE, MAINTENANCE OR THE FINAL DIS-
POSAL OF THIS UNIT.
WHEN THE SYSTEM IS FUNCTIONING PROPERLY AND
THE OWNER HAS BEEN FULLY INSTRUCTED, SECURE
THE OWNER'S APPROVAL.
PRESSURE
TEMP. °F
PSIG
75
217.40
90
76
220.90
91
77
224.40
92
78
228.00
93
79
231.60
94
80
235.30
95
81
239.00
96
82
242.70
97
83
246.50
98
84
250.30
99
85
254.10
100
86
258.00
101
87
262.00
102
88
266.00
103
89
270.00
104
PRESSURE
PRESSURE
TEMP. °F
PSIG
274.10
105
278.20
106
282.30
107
286.50
108
290.80
109
295.10
110
299.40
111
303.80
112
308.20
113
312.70
114
317.20
115
321.80
116
326.40
117
331.00
118
335.70
119
Unitary Products Group
PSIG
340.50
345.30
350.10
355.00
360.00
365.00
370.00
375.10
380.20
385.40
390.70
396.00
401.30
406.70
412.20