12-4 Main Part Inspection Method

Part
Room Temperature Sensor
Room Fan Motor
Stepping Motor
Samsung Electronics
Measure resistance with a tester
Normal
At the normal temperature 37kΩ~ 8.3kΩ(-7˚C~+30˚C)
Abnormal
∞, 0Ω . . . Open or Short
Measure the resistance between terminals of the connector (CN73) with a tester.
Normal
At the normal temperature (10˚C ~ 30˚C)
Compare terminal
Yellow, Red
White, Red
Abnormal
∞, 0Ω . . . Open or Short
Measure the resistance between the red wire and each terminal wire with a tester.
Normal
About 300Ω at the normal temperature (20˚C ~ 30˚C)
Abnormal
∞, 0Ω . . . Open or Short
Breakdown Inspection Method
Resistance
47Ω± 10%
57Ω ± 10%
*Refer to Table 12-3-4.
Remark
Main
Sub