EXCELL PRECISION CO., LTD
CHAPTER 5 ADVANCED FUNCTIONS
5-1. Auto Power off and Backlight Settings
Switch on the scale, press the
function settings mode. The display shows
Use the
ON/ZERO
enter a parameter
Press the
TARE
Use the
ON/ZERO
enter a parameter
Automatic Power-off Function
When the weight on weigh pan is less than 10d or remains steady for the set time, the scale
will automatically switch off.
v Automatic power-off is not functional when using an ac adaptor as the power source.
Therefore, auto power-off is active ONLY when using dry batteries as the power source.
Auto Backlight Function
When the weight is over 10d, the backlight is on. After the weight is stable for 10 seconds or
when the scale returns to zero, the backlight switches off.
SK-VET V1.0
ON/ZERO
key to
key
key to
NEXT
PAGE
.
and the
keys together to enter the advanced
HOLD
The display shows the current setting
Auto power off timer setting
Use the
0 ⇒ No auto power-off
1 ⇒ When the scale is idle for 1 minute, the
scale automatically switches off
2 ⇒ When the scale is idle for 2 minutes, the
scale automatically switches off
19 ⇒ When the scale is idle for 19 minutes,
the scale automatically switches off
The display shows the current setting
Auto backlight setting
Use the
on ⇒ Auto Backlight on
off ⇒ Auto Back light off
ON/ZERO
⇒ Confirm / enter key
TARE
⇒ Move the cursor to the right
HOLD
19
。
key to enter a parameter.
ON/ZERO
key.
ON/ZERO
⇒ Increment digit (from 0 to 9)