SRX 5600 and SRX 5800 Services Gateway Switch Control Board Installation Instructions
Figure 2: Removing an SCB

Installing an SCB

To install an SCB (see Figure 3 on page 8):
1.
2.
3.
4.
5.
6.
7.
6
Replacing an SCB
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and
connect the strap to one of the ESD points on the chassis. For more information
about ESD, see "Preventing Electrostatic Discharge Damage" on page 8.
If you have not already done so, power off the device as described in "Powering
Off the Services Gateway" on page 4.
Carefully align the sides of the SCB with the guides inside the chassis.
Slide the SCB into the chassis until you feel resistance, carefully ensuring that it
is correctly aligned.
Grasp both ejector handles and rotate them simultaneously clockwise until the
SCB is fully seated.
Place the ejector handles in the proper position, horizontally and toward the
center of the board.
Switch the circuit breaker or toggle switch for each power supply to the
position to start the device. The
blink, then light steadily.
OK
LED on the power supply faceplate should
ON