Child Proof Lockout (CP)
The transmitter contains a "Child Proof" lockout feature that
prevents unauthorized use of the remote control. To access
the "Child Proof" activation button, remove cover on BACK
of transmitter. To activate LOCKOUT:
1. Press and hold in the "setting button" for 5 seconds. The
letters CP will display on the LCD screen (see Figure
13). This prevents the activation of fi replace. When any
function button is pressed ON/OFF etc. the letter CP
will display on the LCD screen.
To deactivate LOCKOUT:
1. Press and hold in the "setting button" for 5 seconds. The
LCD will display CP until 5 seconds have elapsed, and
then the LCD screen will return to its normal state.
TRANSMITTER SAFETY FEATURES
It is recommended that the TRANSMITTERS always be
located within a 20 foot operating range of the fi replace,
preferably in the same room in which the fi replace system
is located. The TRANSMITTER features several safety
features that alert the user when the TRANSMITTER is
placed outside the 20 foot normal operating range.
Thermo-Safety and Communication-Safety Features
This remote control has both a THERMO-SAFETY and
COMMUNICATION-SAFETY function built into its software.
It provides an extra margin of safety when the TRANSMIT-
TER is out of the normal 20 foot operating range of the
receiver. It is also activated when the batteries become
weak or are removed from the transmitter.
In the THERMO-SAFETY feature (only in the THERMO or
TIMER modes) the transmitter normally reads the ROOM
temperature every 2 minutes. In addition to checking the
temperature, the transmitter sends a signal to the receiver in-
dicating that the transmitter and its batteries are still active.
In the COMMUNICATION-SAFETY feature, at all times
and in all OPERATING MODES the transmitter sends a
signal every fi fteen (15) minutes to the receiver, indicating
that the transmitter is within the normal operating range
of 20 feet.
Should the receiver NOT receive a transmitter signal every 2
minutes (THERMO-SAFETY feature) or 15 minutes (COM-
MUNICATION-SAFETY feature), the RECEIVER will begin a
2 HOUR (120 minute) countdown timing function. If during this
2 hour period, the receiver does not receive a signal from the
transmitter, the RECEIVER will shut down the fi replace being
controlled by the receiver. The RECEIVER will then emit a
series of rapid "beeps". Then, after 10 rapid "beeps", the RE-
CEIVER will continue to emit a single "beep" every 4 seconds
until a transmitter signal is again received. The intermittent 4
second beeping will go on indefi nitely until reset.
To "reset" the RECEIVER and operate the fi replace system:
1. Press the MODE button on the transmitter. The word
ON must display on the LCD screen. The THERMO-
SAFETY and COMMUNICATION -SAFETY operation is
overridden and the system will return to normal operation
depending on the MODE selected at the transmitter.
Hearth & Home Technologies • SMART-BATT-II Remote Control Instructions • 100-909 Rev. i • 5/12
10
We recommend the user check the batteries in the
TRANSMITTER to make sure the voltage is no less than
2.7 volts.
Auto Shutdown
This remote control has an Auto Shutdown feature incor-
porated into its system. When the transmitter MODE is
in the ON position the fi replace will continuously operate
for 9 hours. After 9 hours, the fi replace will shut down. To
relight the fi replace:
1. Press the MODE button.
The transmitter must be positioned within a 20 foot operat-
ing range for the Auto Shutdown feature to operate.

SYSTEM CHECK

Millivolt Valves
Light the appliance following the lighting instructions that
came with the fi replace. Confi rm that the pilot fl ame is on.
It must be in operation for the main gas valve to operate.
1. Slide the 3-position button on the remote receiver to the
ON position. The main gas fl ame (i.e., the fi re) should
ignite.
2. Slide the button to OFF. The fl ame should extinguish
(the pilot fl ame will remain on).
3. Slide the button to REMOTE (the center position), then
press the MODE button on the transmitter to change
the system to ON. The main gas fl ame should ignite.
4. Press the MODE button on the transmitter to change
the system to OFF. The fl ame should extinguish (the
pilot fl ame will remain on).
5. Press the MODE button on the transmitter to change
the system to THERMO.
6. Advance the SET temperature on the transmitter to a
temperature of at least 2 ºF (1 ºC) above the ROOM
temperature displayed on the LCD screen and the
system fl ame will ignite.
7. Set the SET temperature to at least 2 ºF (1 ºC) below
the room temperature and the system fl ame will extin-
guish. Thereafter, it should continue to cycle on and
off thermostatically approximately every two minutes
as the ROOM temperature changes, but only when
the temperature differential between ROOM and SET
temperatures differs at least 2 ºF (1 ºC). The 2 ºF dif-
ferential is the factory setting.
Electronic Ignition System
1. Slide the 3-position button on the remote receiver to the
ON position. The spark electrode should begin spark-
ing to ignite the pilot (the pilot may ignite after only one
spark). After the pilot fl ame is lit, the main gas valve
should open and the main gas fl ame should ignite.
2. Slide the button to OFF. The main gas fl ame and pilot
fl ame should BOTH extinguish.
3. Slide the button to REMOTE (the center position).