e. Check to ensure the light goes off when the purifier power
switch is set to off, when the blower goes off, or when the
HVAC system power is turned off.
Evolutiont Air Control
When the Perfect Air Purifier is used with an Evolution Control,
the Evolution Control can be configured to remind the homeowner
when it is time to change the purifier cartridge. This maintenance
reminder can be based on either the TrueSenset dirty filter
algorithm or time. The installer should use their discretion to select
the most appropriate option based on the initial system static
pressure.
Maximizing Performance
Maximum air purification performance is obtained when the
furnace blower is set for continuous operation on the thermostat or
Evolution Control.

MAINTENANCE

The purifier is designed to require minimal maintenance.
Maintenance is limited to the replacement of the air purification
cartridge and inspection/brush cleaning of the ionization array.
Frequency of air purifier cartridge replacement and cleaning of the
ionization array may vary depending on ductwork design and local
environmental conditions, generally 8- -12 months.
WARNING
!
FIRE HAZARD
Failure to follow this warning could result in personal injury
or equipment damage.
Use of non- -factory approved filter cartridge will void the
warranty and may cause damage due to fire.
To replace the air purifier cartridge, complete the
following steps:
Turn the heating and cooling system power
off.
WARNING
!
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury
or death.
Before installing or servicing system, always turn off main
power to system. There may be more than one (1) disconnect
switch.
Turn the purifier switch to the off position.
Remove the purifier door.
Slide out the old air purifier cartridge and discard.
Install the new air purifier cartridge. Make sure the power cord is
flexed out of the way to avoid damage to the air purifier cartridge
pleats during insertion.
NOTE: Verify that the air purifier cartridge is installed correctly.
Make sure that the arrows on the air purifier cartridge point toward
the fan coil. This should be in the same direction as airflow and
match the arrows on the sticker inside the cabinet.
Replace the purifier door.
Turn the purifier switch to the on position.
Turn heating and cooling system power on.
WARNING
!
CARBON MONOXIDE HAZARD
Failure to follow this warning could result in personal injury
or death.
Do not remove door during blower operation or operate
blower with door removed or improperly latched.
Power Indicator
Fig. 10 - - Power Indicator
At the time of air purifier cartridge replacement, if a powdery
residue is noticed on the tips of the points in the ionization array,
proceed to clean them by completing the following steps.
Turn heating and cooling system power off.
WARNING
!
ELECTRICAL
SHOCK
HAZARD
Failure to follow this warning could result in personal injury
or death.
Before installing or servicing system, always turn off main
power to system. There may be more than one (1) disconnect
switch.
Turn the purifier switch to the off position.
Remove the purifier door.
Unplug the power cord from the enhancement module.
Slide out the enhancement module assembly and safety screen.
WARNING
!
CUT HAZARD
Failure to follow this warning could result in personal injury.
Sheet metal parts may have sharp edges or burrs. Use care and
wear appropriate protective clothing and gloves when
handling parts.
Slide out the safety screen and set aside.
NOTE: Best cleaning tools: 5- -in (127 mm) handle paint brush
with 2- -in (51 mm) width (or greater) brush point (synthetic or
7
A06065
AND
HIGH
VOLTAGE