(8)Press the
key to shift to the next parameter.
SET
(9)Re-set Pr. 79 "operation mode" according to the operation mode to be used.
Note: 1. If the Pr. 903 or Pr. 905 (gain adjustment) value is changed, the Pr. 20 value
does not change.
2. When the Pr. 903 or Pr. 905 value is set, the value of Pr. 38 "frequency at
5V (10V) input" or Pr. 39 "frequency at 20mA input" changes automatically.
Be careful when setting the bias frequency at 0V to any value other than
"0". Even without the speed command, the motor will start running at the
set frequency by merely switching on the start signal.
CAUTION
162