8-2-4. Diagnostic Procedure for Each Check Code (Indoor Unit)

Check code

[E01 error]

Is inter-unit cable of A and B normal?
Is there no disconnection or
contact error of connector on harness
from terminal block of indoor unit?
NO
Is group control operation?
Is power of all indoor units turned on?
Is power supplied to remote controller?
AB terminal: Approx. DC18V
Are 2 remote controllers set
without master unit?

[E09 error]

Are 2 header units set in
2 remote controllers?
[E02 error]
Communication wires
between wired remote controller and
indoor unit connected properly?
NO
YES
YES
NO
YES
NO
YES
NO
YES
YES
NO
YES
NO
NO
YES
Correct inter-unit cable of remote controller
Correct connection of connector.
Check power connection of indoor unit.
Check indoor P.C. board (MCC-1570).
Correct a header unit/a follower unit.
(Remote controller address connector)
Check remote controller P.C. board.
Correct as a header unit and a follower unit.
Check remote controller P.C. board.
Correct communication wire.
Failure of wired remote controller tranmitter
→ Replace wired remote controller.
52
FILE NO. SVM-12004
Check circuit wiring.
(Turn on power again.)
Defect → Replace
Defect → Replace
Defect → Replace

Hide quick links: