Dometic 641515.301 Installation Instructions Manual page 5

Roof top air conditioners & heat pumps
Table of Contents

Advertisement

a. This supply line must be located in the front
portion of the 14-1/4" x 14-1/4" (±1/8") open-
ing.
b. Make sure that at least 15" of supply wire
extends into the roof opening.
c. In a multiple zone installation, this wiring is
required in only one of the 14-1/4" x 14-1/4"
(±1/8") openings.
3. If a Remote Temperature Sensor is used, the
connector end must be routed from the sensor
location to the roof opening of the system which
it will control. Make sure that at least 15" of the
sensor cable extends into the roof opening. Refer
to the Remote Sensor Instructions for details of
the installation.
4. If a furnace is to be controlled by the system, the
two furnace thermostat leads must be routed to the
roof opening of the unit that will control it. Make
sure that at least 15" of the furnace thermostat
wires extend into the roof opening.
5. If an Energy Management System (load shed
feature) is to be used with the control, two wires
must be routed to the roof opening of the zone to
be managed. The signal required for this function is
a normally open relay contact. When the EMS calls
for the compressor to shut off, the relay contacts
should close. Make sure at least 15" of the EMS
wires extend into the roof opening.
6. Route a 4-conductor control cable from the Com-
fort Control Center™ mounting position into the
14-1/4" x 14-1/4" (±1/8") roof opening. Make sure
that at least 15" of the wire extends into the roof
opening and 6" extend from the wall at the mount-
ing position of the Comfort Control Center™. See
Section E-2.
7. In the event that other units are installed (additional
zones) an additional 4-conductor control cable must
be routed to the other units. Make sure that at least
15" of the wire extends into the roof opening. See
FIG. 18.
8. If an automatic generator start kit (AGS) will be in-
stalled, a 4-conductor control cable must be routed
from the last unit (zone) to location of the control
box that will operate the AGS system. Follow AGS
kit instructions for installation.
E. Dometic Comfort Control Center™ & Cable
Installation
1. Location
a. If the system is to be used WITHOUT a Remote
Temperature Sensor, the proper location of
the Comfort Control Center™ is very impor-
tant to ensure that it will provide a comfortable
RV temperature. Observe the following rules
when selecting a location:
Locate the Comfort Control Center™ 54"
above the fl oor.
Install the Comfort Control Center™ on
a partition, not on an outside wall.
641515, 641516, 641535, 651515 & 651516 Installation Instructions
NEVER expose it to direct heat from lamps,
sun or other heat producing items.
Avoid locations close to doors that lead
outside, windows or adjoining outside
walls.
Avoid locations close to supply registers
and the air from them.
b. If the system is to be used WITH a Remote
Temperature Sensor in ALL zones, the
Comfort Control Center
anywhere that is convenient in the coach. Try to
avoid hard to reach and hard to see areas.
Refer to the instructions provided with the
Remote Temperature Sensor for details
of installation.
c. A 3/8" diameter hole will be needed to route
the cable through the wall. See Section D-3.
2. Control Cable Installation
A 4-conductor control cable must be routed from the
roof opening to the Comfort Control Center
a. Choose the shortest, most direct route from
the 14-1/4" x 14-1/4" (±1/8") opening to the
Comfort Control Center
Leave 6" of cable extending through the wall.
See Section D-6.
b. The control cable that should be used is a fl at,
4-conductor telephone cable.
c. The control cable must be terminated with two
(2) RJ-11-6C4P telephone connectors. Refer
to the crimp tool manufacture for crimping
instructions.
Important:
RJ-11-6C4P connectors must be installed
as shown in FIG. 4, 5 & 6.
FIG. 4
FIG. 5
FIG. 6
5
TM
may be mounted
TM
location selected.
Pin 1
RJ-11-6C4P Connector
Flat Four Conductor Cable
TM.