Step 9 Finishing - Heat-N-Glo 6000TRS-CE Installer's Manual

Fireplace
Table of Contents

Advertisement

CAUTION
OPTIONAL WALL SWITCH
THERMOSTAT OR REMOTE
Figure 29. Standing Pilot Ignition Wiring Diagram
Step 9
Finishing
Only non-combustible
materials may be used
to cover the black
fireplace front.
32
ON/OFF
REMOTE SWITCH
SWITCH
PIGTAIL
Figure 30.
WARNING: DO NOT CONNECT 230 V AC
!
TO THE WALL SWITCH OR THE
CONTROL VALVE WILL BE DESTROYED.
LABEL ALL WIRES PRIOR T O DISCONNECTION
WHEN SERVICING CONTROLS. WIRING ER-
RORS CAN CAUSE IMPROPER AND DANGER-
OUS OPERATION. VERIFY PROPER OPERA-
TION AFTER SERVICING.
TP/TH
TP
OFF
TH
ON
THERMOPILE
The following diagram shows the minimum vertical
and corresponding maximum horizontal dimensions
of fireplace mantels or other combustible projections
above the top front edge of the fireplace. See Figures
2 , 3 and 4 for other fireplace clearances.
7.6 10.2
5
NOTE: ALL DIMENSIONS SHOWN
IN CENTIMETERS
Minimum Vertical and Maximum
Horizontal Dimensions of Combustibles
above Fireplace
WARNING: WHEN FINISHING THE
!
FIREPLACE, NEVER OBSTRUCT OR
MODIFY THE AIR INLET/OUTLET
GRILLES IN ANY MANNER.
THERMOCOUPLE
GAS VALVE
o
45
30.5
27.9
25.4
22.7
20.3
15.8
15.2
12.7
TOP FRONT EDGE
OF FIREPLACE

Advertisement