Troubleshooting - Briggs & Stratton Elite series Owner's Manual

3400 psi elite series
Hide thumbs Also See for Elite series:
Table of Contents

Advertisement

TROUBLESHOOTING

Problem
Pump has following problems:
failure to produce pressure,
erratic pressure, chattering, loss
of pressure, low water volume.
Detergent fails to mix with spray.
Engine shuts down during
operation.
3400 PSI Pressure Washer
Cause
1.
Low pressure spray tip installed.
2.
Water inlet is blocked.
3.
Inadequate water supply.
4.
Inlet hose is kinked or leaking.
5.
Clogged inlet hose strainer.
6.
Water supply is over 100°F.
7.
High pressure hose is blocked or
leaks.
8.
Gun leaks.
9.
Spray tip is obstructed.
10. Pump is faulty.
1.
Detergent siphoning tube is not
submerged.
2.
Chemical filter is clogged or
cracked.
3.
Dirty in-line filter.
4.
High pressure spray tip installed.
Out of gasoline.
16
Correction
1.
Replace spray tip with high
pressure spray tip.
2.
Clear inlet.
3.
Provide adequate water flow.
4.
Straighten inlet hose, patch leak.
5.
Check and clean inlet hose
strainer.
6.
Provide cooler water supply.
7.
Clear blocks in outlet hose.
8.
Replace gun.
9.
Clean spray tip.
10. Contact authorized service
facility.
1.
Insert detergent siphoning tube
into detergent.
2.
Clean or replace filter/detergent
siphoning tube.
3.
See "Check In-Line Filter".
4.
Replace spray tip with low
pressure spray tip.
Fill fuel tank.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Elite 01808

Table of Contents